VENTING INSTALLATION
Continued
Note: Vertical (V
1
) + Vertical (V
2
) = 40' max.
Figure 23 - Vertical Venting
Configuration Using Two 90° Elbows
(Vertical Round High Wind Termination
Shown)
45° Elbow
Figure 24 - Vertical Venting Configuration
With No Horizontal Run (Vertical Round
High Wind Termination Shown)
45°
Elbow
HIGH ALTITUDE INSTALLATION
Your FMI PRODUCTS, LLC direct-vent
fireplace has been tested and approved for
elevations from 0-2000 feet (USA) and eleva
-
tions from 0-4500 feet (Canada).
Fireplaces for High Altitude (models ending
in -HA) are for installation above 4000 feet
only. These fireplaces are equipped with parts
specific for higher altitudes.
When installing a non-high altitude fireplace
at an elevation above 2000 feet (in the USA),
you may need to decrease the input rating
Note: Install
restrictor into inner
collar of fireplace
as shown.
Venting with Two 90° Elbows
Vertical (V
1
) Horizontal (H)
5' min.
6' max.
6' min.
12' max.
7' min.
18' max.
8' min.
20' max.
Vertical Venting
V = 40' max.
Note: Install restrictor
into inner collar of
fireplace as shown.
by changing the existing burner orifice to
a smaller size. Reduce input 4% for each
1000 feet above sea level. Check with your
local gas company for proper orifice size
identification.
When installing this fireplace at an elevation
above 4500 feet (in Canada), check with local
authorities.
IMPORTANT:
For horizontal installations
above 2,000 feet, it is recommended that a
12" extension pipe be added before starter
elbow (see Figure 25, page 18) and a round
horizontal termination be used.