MANUAL LIGHTING
PROCEDURE
1. Remove glass door (see
Removing/Re-
placing Glass Door
, page 25).
2. Follow steps 1 through 8 under
Lighting
Instructions
, page 28.
3. Press gas control knob and light pilot with
match.
4. Keep gas control knob pressed in for
30 seconds after lighting pilot. After 30
seconds, release gas control knob. Fol
-
low steps 9 through 12 under
Lighting
Instructions, page 28
.
5. Replace glass door (see
Removing/Re-
placing Glass Door
, page 25).
OPTIONAL HAND-HELD
REMOTE OPERATION
Note: All remote control accessories must
be purchased separately (see Accessories,
page 42). Follow instructions included with
remote control.
NOTICE: You must light the pilot
before using the hand-held re
-
mote control unit. See
Lighting
Instructions
, page 28.
After lighting, let pilot flame burn for about
one minute. Turn control knob to ON position.
Adjust flame adjustment knob anywhere be
-
tween HI and LO. Slide selector switch to the
REMOTE position (see Figure 45).
Note: Burner may light if hand-held remote
was on when selector switch was last turned
off. You can now turn burner on and off with
hand-held remote control unit.
IMPORTANT:
Do not leave selector switch in
the REMOTE or ON position when pilot is not
lit. This will drain the battery.
OF
F
PIL
O
T
LO
IH
ON
OFF
REMOTE
ON
OFF
O
N
Blower Control Knob (Optional Accessory)
Variable Control Knob
Selector Switch in
Remote Position
Gas Control Knob
in ON Position
Figure 45 - Setting Selector Switch, Gas
Control Knob and Variable Control Knob
for Remote Operation
OPERATION
Continued
OPERATING OPTIONAL
GWMT1 - WALL MOUNTED
THERMOSTAT
WARNING: Do not con-
nect the thermostat to a power
source. Electrical shock and/or
a fire hazard will occur.
Light fireplace as instructed in
Lighting In-
structions
on page 28. Set wall thermostat to
desired temperature.
This thermostat has been electronically cali
-
brated at the factory and requires no adjust
-
ment or leveling.
Upon installation, thermostat must be allowed
to stabilize at room temperature for a mini
-
mum of 30 minutes for proper operation.
To turn fireplace off, adjust thermostat to the
lowest setting and turn gas control knob back
to PILOT. The pilot will remain lit.
IMPORTANT:
To turn pilot off, turn gas control
knob on heater to the OFF position.
OPERATING OPTIONAL
BLOWER ACCESSORY
Locate blower controls by opening lower
louver panel on fireplace. Blower controls are
located on the right side of switch bracket to
the left just inside louver panel.
The BK manual blower and BKT thermostat
-
ically-controlled blower have an ON setting
and an OFF setting. Blower will only run when
switch is in the ON position. In the OFF posi
-
tion, blower will not operate.
Note for BKT Only:
If you are using BKT
blower with optional thermostat (wall mounted
or remote control) for fireplace, your fireplace
and blower will not turn on and off at the same
time. Fireplace may run for several minutes
before blower turns on. After heater modulates
to the pilot position, blower will continue to run.
Blower will shut off after firebox temperature
decreases.
The blower helps distribute heated air from the
fireplace. Periodically check louvers of firebox
and remove any dust, dirt or other obstruc
-
tions that will hinder the flow of air.