VenTing inSTallaTion

Continued

Nail Only 

Outer 

Perimeter 

of Flashing

Storm 

Collar

Flashing

Cone

Underlap 

Shingles 

at Bottom

Overlap 

Shingles Top 

and Sides Only

Figure 24 - Flashing Installation

PENETRATING ROOF

To maintain a 2" clearance to pipe on a roof with 

a pitch, a rectangular opening must be cut.
1.  Determine the center point through which 

pipe will penetrate roof.

2.  Determine center point of roof. Pitch is the 

distance the roof drops over a given span, 

usually 12". A 6/12 pitch means that the 

roof drops 6" for each 12" one measure 

horizontally down from roof rafters.

3.  Use  roof  opening  chart  (Figure  23)  to 

determine  correct  opening  length  and 

flashing required.

4.  Remove shingles around opening mea-

sured. Cut out this section.

5.  Add  next  sections  of  pipe  until  end 

penetrates  roof  line.  Check  to  see  that 

proper clearances are maintained. Extend 

chimney by adding sections of double wall 

pipe until pipe is minimum of 30" above 

highest point of roof cutout. Termination 

and chimney must extend a minimum of 

36" above highest point where it passes 

through the roof.

Figure 25 - Storm Collar

Chimney 

Pipe

Waterproof 

Caulk

Storm 

Collar

Flashing

FLASHING INSTALLATION

Determine flashing to be used with roof open-

ing chart. Slide flashing over pipe until base is 

flat against roof. Replace as many shingles as 

needed to cover exposed area and flashing 

base. Secure in position by nailing through 

shingles  (see  Figure  24).  DO  NOT  NAIL 

THROUGH FLASHING CONE.

STORM COLLAR INSTALLATION 

(SC-10)

Place storm collar over pipe and slide down 

until it is snug against the open edge of the 

flashing (see Figures 24 and 25). Apply wa-

terproof  caulking  to  all  seams  and  notches 

around  storm  and  also  at  base  around 

shingles.

Pitch

Slope Opening 

"A" Max. 

Used Flashing

Model No. 

Flat

19"

V6F-10DM

0-6/12

26.6°

23.25"

V6F-10DM

6/12-

12/12

56.3°

30.75"

V12F-10DM

Figure 23 - Roof Opening Measurements

Opening

“A”

19" Min.

(48.26cm)

30" Min.

(76.2cm)

2" Min.

(5.08cm)

2" Min.

(5.08cm)

2" Min.

(5.08cm)

TERMINATIONS

The fireplace system must be terminated with 

the listed round top or chase terminations. In 

any case, refer to the installation instructions 

supplied with the termination. 
Terminations approved for this fireplace are 

RLT-12D, which can be used for flashing or 

chase and STL-12D for chase style termina-

tion only. Figure 26, page 11, shows an RLT-

12D round top termination.

 CAUTION: Do not seal open-

ings on the rooftop flashing. Fol-

low the installation instructions 

provided  with  the  termination 

being used.

Summary of Contents for (V)3612ST

Page 1: ...roved to ANS Z21 60 or Z21 84 standards or for use with a vent free gas log heater approved to ANS Z21 11 2 standard This wood burning fireplace complies with UL127 CAN ULS S610 M87 standard as a FACTORY BUILT APPLIANCE FOR CANADA The authority having jurisdiction such as the municipal building department fire department etc should be contacted before installation to deter mine the need to obtain ...

Page 2: ... place clothing or other flammablematerialsonornear the appliance Never leave children unat tended when a fire is burning in the fireplace IMPORTANT Check local codes before installing this fireplace Models V 3612STseriesisawoodburningfire place intended and approved for installation in either residential homes or buildings of standard construction This fireplace system requires the utilization of...

Page 3: ...ARNING Use solid wood or processed solid fuel fire logs only When processed wood fuel fire logs are used do not poke or stir the logs while they are burning Use only fire logs that have been evaluated for the application in fireplace and refer to fire log warnings and caution markings on packaging prior to use WARNING Always leave glass doors fully opened or fully closed when operating fireplace W...

Page 4: ...acers on Sides of Fireplace Provide Required 1 2 5 cm Clearance 2 5 cm Min Clearance From Pipe to Combustibles 3 7 6 cm 12 30 4 cm Min From Perpendicular Side Wall to Fireplace Opening Typ Figure 3 Fireplace Clearances selecting location To determine the safest and most efficient location for the fireplace you must take into consideration the following guidelines 1 The location must allow for prop...

Page 5: ...r should extend under fireplace a minimum of 1 1 2 The ember protector should be made of galvanized sheet metal 28 gauge minimum to prevent corrosion 6 Using screws or nails secure fireplace to the framing through flanges located on sides of the fireplace see Figure 8 Fireplace Installation Continued Figure 7 Ember Protectors Ember Protector Typ of 2 1 2 1 2 cm Maximum Figure 8 Nailing Flanges Nai...

Page 6: ...NSION 52 1 2 MIN 133 3cm 36 1 2 MIN 92 7cm 8 MIN 20 3cm 16 MIN 40 6cm Figure 9 Hearth Extensions the front face must not be placed within 9 of fireplace opening Combustible materials above and projecting more than 1 1 2 from the fireplace front face see Figure 11 must not be placed less than 12 from effective opening of the fireplace NFPA STD 211 Sec 7 3 3 3 Mantels or any other combustible materi...

Page 7: ...imney together exception see Figure 17 page 8 WARNING The opening in the collar around the chimney at the top of the fireplace must not be obstructed Neveruseblowninsula tion to fill the chimney enclosure Figure 13 Outside Air Kit Installation Secure to Collars with Duct Tape or Screws Air Inlet Location Must Allow For Bushes or Snow Vent Hood Required for Wall Installation Air Inlet Termination V...

Page 8: ...stop Spacers FS 10 Firestop spacers are required at each point where the chimney penetrates a floor or ceil ing joist space Their purpose is to establish and maintain the required clearance between the chimney and the combustible materials When the pipe passes through a framed opening into a living space above the firestop must be placed onto the ceiling from below as shown in Figure 19 page 9 The...

Page 9: ... flue pipe MINIMUM HEIGHT 15 FT 4 5m MAXIMUM HEIGHT CHASE TERMINATION 40 FT 12m Figure 22 Maximum Chimney Height Storm Collar Flashing Firestop Spacer RLT 12D RLT 12D STL 12D Minimum Maximum Chimney Height The minimum height of the chimney mea sured from the base of the fireplace to the flue gas outlet end of pipe is 16 feet for a straight run 16 feet minimum for a run with 1 elbow set and 25 feet...

Page 10: ...roof Caulk Storm Collar Flashing Flashing Installation Determine flashing to be used with roof open ing chart Slide flashing over pipe until base is flat against roof Replace as many shingles as needed to cover exposed area and flashing base Secure in position by nailing through shingles see Figure 24 DO NOT NAIL THROUGH FLASHING CONE Storm Collar Installation SC 10 Place storm collar over pipe an...

Page 11: ... tile or other noncom bustible materials may overlap the front face provided they do not obstruct essential open ings like louvered slots or any other opening When overlapping with a noncombustible facing material use only noncombustible mortar or adhesive Installing fireplace facing Any noncombustible material may be used for facing glass tile brick etc as long as proper clearances are adhered to...

Page 12: ...ping approved by local codes When installing a gas line a shutoff valve designed for installation outside the appliance is recommended The gas pipe is intended for connection to a decorative gas appliance that operates using natural or propane LP gas only This appliance must have an automatic shutoff device and must comply with the Standard for Decora tive Gas Appliances for Installation in Vented...

Page 13: ...ge 15 must be installed when using an unvented gas log set Operation and Maintenance Guidelines Glass Doors Bi fold glass doors are optional with this fireplace Check with your local distributor for availability To install glass doors refer to installation instructions that are included with kit When fireplace is in operation doors must be fully open or fully closed position only or a fire haz ard...

Page 14: ...erials Chimney Have your chimney system cleaned and in spected regularly to ensure safe and efficient operation damper Mechanism The damper control lever is located inside the fire chamber see Figure 32 Make sure lever is cool before handling Pull down to close and push up to open Damper must be open when lighting a fire Not doing so will cause smoke spillage into the room When fireplace is not in...

Page 15: ...in triple wall Double Wall Pipe support assembly 12S 12DM Also available in triple wall Outside Air Kit AK4 Vent Plaster Collar Vent Hood Connector Duct 4 x 3 Storm Collar SC2 1 Firestop Spacer FS 10 for Straight Pipe 30FS 10 for 30 Angled Run Flashing V6F 10DM 0 to 6 12 Pitch V12F 10DM 6 12 to 12 12 Pitch Round Top Termination RLT 12D Econo Top Termination STL 12D Bi Fold Glass Doors DG368ST Brus...

Page 16: ...115603 01 Rev D 09 09 2701 S Harbor Blvd Santa Ana CA 92704 1 866 328 4537 www fmiproducts com ...

Reviews: