6.
Noncombustible Exterior Wall:
Position the
horizontal vent cap in the center of the 8
1
/
2
" round hole and attach to the exterior
wall with four screws.
Note:
The four wood
screws provided should be replaced with
appropriate fasteners for stucco, brick,
concrete or other types of sidings. Before
attaching the vent cap to exterior wall, run
a bead of non-hardening mastic (pliable
sealant) around the outside edges to make
a seal between it and the outside wall.
Combustible Exterior Wall:
For vinyl siding,
stucco or wood exteriors, a siding standoff
may be installed between the vent cap
and exterior wall. The siding standoff
prevents excessive heat from damag-
ing the siding materials. Siding material
must be cut to accommodate standoff.
Bolt the vent cap to the standoff. Apply
non-hardening mastic around outside
edge of standoff. Position the standoff/
cap assembly in the center of the 11
1
/
2
"
square hole and attach to exterior wall
with wood screws provided (see Figure
11). The siding standoff must sit flush
against the exterior fascia material.
7.
Combustible Exterior Wall Only:
Slide the
wall firestop over the vent pipe before
connecting horizontal run to vent cap (see
Figure 12).
8. Carefully move fireplace, with vent as
-
sembly attached, toward wall and insert
vent pipe into horizontal termination. The
pipe overlap should be a minimum of 1
1
/
4
"
(see Figure 13, page 13).
9.
Combustible Exterior Wall Only
: Slide wall
firestop against interior wall surface and
VENTING INSTALLATION INSTRUCTIONS
Continued
Figure 10 - Installing Horizontal Vent Cap
(Noncombustible Exterior)
Figure 11 - Installing Siding Standoff
(Combustible Exterior)
Wood
Screw
Vent
Cap
Cut Siding Away to
Fit Standoff
Wood Screw
Screws
Standoff
Vent Cap
Apply Mastic
to All Four Sides
attach with screws provided (see Figure
12). See Figure 13, page 13 for horizontal
termination details.
10. Place fireplace into position and shim with
noncombustible material if needed. Nail or
screw side flanges to framing to secure
unit in place.
IMPORTANT:
Make sure fire
-
place is level before securing. If fireplace
is not level it will not work properly.
Vent Cap
(Horizontal
Termination)
Interior Wall
Surface
Wall
Firestop
Horizontal
Vent Pipe
Figure 12 - Connecting Vent Cap with