15

Raised and Flush Hearth Application:

If you would prefer to have a raised hearth, the Vent-Free box 

can be raised to the desired height using wood studs or concrete 

blocks.

Figure 26

Concrete Block 

Raised Platform

 

When determining raised hearth height, be sure to allow 

for the 3” thick firebox hearth and 1-1/2” thick firebrick floor, in 

addition to the height of base platform.

Figure 27

Raised Wood 

Platform

 

For a “flush hearth” (fireplace floor flush with the room’s 

floor) the base plate can be omitted from the assembly and the 

firebox  walls  built  directly  on  the  concrete  support  slab.  The 

fire brick floor of the firebox is then set directly to the concrete 

support slab. This makes the fireplace finished fire brick floor 

approximately one and one-half inches (1-1/2”) above the top 

of the concrete support slab. 

Gas Piping Installation

 

The  provision  for  installation  of  a  gas  pipe  is  only  for 

connection  to  a  Vent  free  decorative  gas  log  sets  meeting 

standard ANSI Z21.11.2

 

Familiarize  yourself  with  requirements  for  installation  as 

outlined by the National Fuel Gas Code, ANSI Z223.1.

 

This  gas  pipe  provision  must  only  be  connected  to  an 

approved  vent-free  gas  log  heater  certified  to ANSI  Z21.11.2 

heater  standard.  Check  local  building  codes  for  specific  pipe 

and material requirements.

1)  Gas piping can be routed from the floor, rear or side walls. 

With  a  masonry  drill,  follow  the  instructions  from  the  gas 

appliance manufacturer. Any wires must be routed through 

separate conduit. Make sure provisions are made for access 

to manual shut-off valve.

Figure 28

CSA  Certified  Manual 

Shut-off Valve

Tee-joint

Sediment 

Trap

Approved 

Flexible 

Gas Line

3” 

Minimum

Pipe 

Nipple

Cap

From External

 Regulator 

(11-14” W.C. pressure)

2)  After routing piping, fill hole around pipe with mortar.

Electrical Line Feed

 

Electrical  line  feed  can  be  routed  through  the  Standard 

firebox  back wall, side walls or floor by drilling an appropriately 

sized  hole  using  a  masonry  drill  bit.  Be  sure  to  follow  the 

Vent free decorative gas log Manufacturer’s explicit electrical 

line  connection  instructions  for  vented  masonry  fireplace 

installations.

NOTE: Gas line and electric line must be routed through 

separate access holes.

Firebrick Side

Gas or

Electric Line

Figure 29

IMPORTANT

All access holes must be grouted with mortar to 

seal any gaps or cracks.

Summary of Contents for Masonry MM39

Page 1: ...and approved by PFS under ANSI Z21 91 for use with any ANSI Z21 11 2 approved gas logs FORUSEONLYWITHALISTEDGAS FIREDUNVENTED DECORATIVE ROOM HEATER NOT TO EXCEED 40 000 BTU HR DO NOT BUILD A WOOD FI...

Page 2: ...WITH ANSI Z21 91 2007 VENTLESS FIREBOX ENCLOSURES FOR GAS FIRED UNVENTED DECORATIVE ROOM HEATERS FOR USE WITH LISTED ANSI Z21 11 2 UNVENTED DECORATIVE ROOM HEATERS NOT TO EXCEED 40 000 BTU HR 0 10 NO...

Page 3: ...d Diagram 5 9 12 2 7 1 3A 2X 2X 3X 7X 2X 8X 3 6 11 Warning Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may re...

Page 4: ...ireplace Parts List ITEM P N DESCRIPTION QTY 1 MFP39 1 MFP44 1 MFP49 1 HEARTH Left or Right 2 2 MFP39 2 MFP44 2 MFP49 2 REAR WALL 4 3 MFP39 3 MFP44 3 MFP49 3 SIDE WALL 7 3A MFP39 3A MFP44 3A MFP49 3A...

Page 5: ...erve as a primary heat source rather the fireplace was expressly created as a supplemental source of heat The Grand Meridian Fireplace is Designed for Use Only with any Vent free decorative gas log se...

Page 6: ...ace if not enough fresh air is available See Air for Combustion and Ventilation page 8 If the fireplace keeps shutting off see appliance manufacturers troubleshooting instructions 9 Do not run firepla...

Page 7: ...ian fireplace Check with the local jurisdiction before you get started Supporting Floor Systems Floor Framing It is important to take into consideration that the load for the Grand Meridian Fireplace...

Page 8: ...dian Fireplace must be considered as additional dead load that will have to be supported by the floor framing Additional floor joists or I joists may be required as determined by the licensed design p...

Page 9: ...d structural members having a moisture content of less than 16 per cent at time of installation and used under dry conditions the deflection resulting from L 0 5D is permitted to be substituted for th...

Page 10: ...designed to be custom finished with facing trim and mantle to be an owner option However all such trim material must meet standard fireplace code requirements Non combustible facing material must be...

Page 11: ...he house to operate You must provide adequate fresh air for these appliances This will insure proper venting of vented fuel burning appliances Non combustible Flex Hose Figure 16 Exterior Providing Ad...

Page 12: ..._ Btu hr Total _ _______ Btu hr Example Gas water heater 40 000 Btu hr Vent free fireplace 36 000 Btu hr Total 76 000 Btu hr Do not include direct vented gas appliances Direct vent draws combustion ai...

Page 13: ...prior to assembly This will minimize shrinkage and cracks developing in the joint areas Best way to accomplish this is with a bucket of water and a large sponge Dip sponge into water and apply a liber...

Page 14: ...28 Apply mortar between joints 12 inch rebar Mix a batch of mortar and prepare Right Side Hearth bottom 2 surface to be bonded as shown in Figure 18 Figure 18 1 2 AWAY FROM EDGES 1 2 MORTAR BEAD TYPIC...

Page 15: ...rebar to all 8 cells as shown in Figure 22 The rebar should enter the holes in the Hearth and lie adjacent to the 12 rebar secured in subfloor Then fill cells with approx 2 cu ft Ready Mix Concrete F...

Page 16: ...Fuel Gas Code ANSI Z223 1 This gas pipe provision must only be connected to an approved vent free gas log heater certified to ANSI Z21 11 2 heater standard Check local building codes for specific pip...

Page 17: ...smells created from the heater and fireplace curing We suggest operating the heater for several 30 minute intervals allowing the fireplace to cool for an hour in between This will allow any moisture i...

Page 18: ...ncrete slab The concrete strength and durability shall comply with Sections 1903 1904 and 1905 of the International Building Code IBC TABLE R402 2 MINIMUM SPECIFIED COMPRESSIVE STRENGTH OF CONCRETE MI...

Page 19: ...ly b Lines defining areas are approximate only Local conditions may be more or less severe than indicated by region classification A severe classification is where weather conditions result in signifi...

Page 20: ...components FMI PRODUCTS LLC is not responsible for misuse or mishandling of component parts Nothing in this warranty makes FMI PRODUCTS LLC or any entity thereof liable in any respect for any injury...

Reviews: