(V)L32HN, (V)L32LHN
• Rating (Variable): 16,000/27,000 Btu/Hr
• Type Gas: Natural
• Ignition: Piezo
• Manifold Pressure: 3.5" W.C.
• Inlet Gas Pressure (in. of water)
Maximum 10.5" W.C., Minimum* 5" W.C.
* For purpose of input adjustment
(V)L36EN, (V)L36LEN
• Rating (Variable): 21,000/33,000 Btu/Hr
• Type Gas: Natural
• Ignition: Piezo
• Manifold Pressure: 3.4" W.C.
• Inlet Gas Pressure (in. of water)
Maximum 10.5" W.C., Minimum* 5" W.C.
* For purpose of input adjustment
SPECIFICATIONS
Manually-Controlled Models
WIRING DIAGRAM
(REMOTE-READY MODELS ONLY)
Thermopile
(V)L32HP, (V)L32LHP
• Rating (Variable): 16,000/27,000 Btu/Hr
• Type Gas: Propane/LP
• Ignition: Piezo
• Manifold Pressure: 8" W.C.
• Inlet Gas Pressure (in. of water)
Maximum 14" W.C., Minimum* 11" W.C.
* For purpose of input adjustment
(V)L36EP, (V)L36LEP
• Rating (Variable): 21,000/33,000 Btu/Hr
• Type Gas: Propane/LP
• Ignition: Piezo
• Manifold Pressure: 7.9" W.C.
• Inlet Gas Pressure (in. of water)
Maximum 14" W.C., Minimum* 11" W.C.
* For purpose of input adjustment
Remote-Ready Models
(V)L36ZNR, (V)L36LZNR, (V)L42ZNR
(V)L42LZNR
• Rating (Variable): 25,000/36,000
• Type Gas: Natural
• Ignition: Piezo
• Manifold Pressure: 3.4" W.C.
• Inlet Gas Pressure (in. of water)
Maximum 10.5" W.C., Minimum* 5" W.C.
* For purpose of input adjustment
(V)L36ZPR, (V)L36LZPR, (V)L42ZPR,
(V)L42LZPR
• Rating (Variable): 25,000/36,000 Btu/Hr
• Type Gas: Propane/LP
• Ignition: Piezo
• Manifold Pressure: 8" W.C.
• Inlet Gas Pressure (in. of water)
Maximum 14" W.C., Minimum* 11" W.C.
* For purpose of input adjustment
Receiver
On
Off
Remote
Red
Red
White
White
Thermopile
Gas Control
TPTH
TH
TPTH TP