9

Figure 5 - Installing Hood 

Screw

Hood

Rail

INSTALLATION

Continued 

Figure 6 - Assembling Perimeter Trim

Side Trim

Slot

Mitered 

Edge

Slot

Shim

Set Screws

Adjusting 

Plate 

Assembled 

Trim

Top 

Trim

Figure 7 - Attaching Perimeter Trim to 

Fireplace

Trim 

Hanging 

Screws

Hanging 

Notches 

on Trim 

Mitered 

Edge

ASSEMBLING AND ATTACHING 

OPTIONAL PERIMETER TRIM

IMPORTANT: 

If you are recessing the firebox 

in a wall, do not attach trim at this time. See 

Built-In Fireplace Installation

, page 11.

Note: These instructions show assembling 

and attaching trim to fireplace.

CHECK GAS TYPE

Use the correct gas type (natural or propane/

LP) for your fireplace. If your gas supply is not 

correct,  do  not  install  fireplace.  Call  dealer 

where you bought fireplace for proper type 

fireplace.

 WARNING: This appliance is 

equipped for natural or propane/

LP gas but not both. Gas type is 

indicated on rating plate. Field 

conversion is not permitted.

ELECTRICAL HOOKUP

This fireplace includes a blower which must 

be connected to either a wall receptacle or 

the electrical receptacle that is included within 

the fireplace. If the receptacle included with 

the fireplace is to be used, it must be wired 

to a 120 volt supply by a certified electrician.

OPTIONAL PANELS

Each fireplace is shipped with louvered panels 

installed.  Smooth panels are also shipped 

with  this  fireplace  and  be  used  if  desired.  

They  allow  for  a  different  appearance. The 

smooth panels may be covered with noncom

-

bustible materials such as ceramic tile or rock.

INSTALLING HOOD

Install hood to rail already installed in fireplace 

as shown in Figure 5. Use 3 Phillips screws 

provided.

1.  Remove packaging from three pieces 

of trim.

2.  Locate four screws, two adjusting plates 

with  set  screws,  and  two  shims  in  the 

hardware packet.

3.  Align shim under adjusting plate as shown 

in Figure 6.

4.  Slide  one  end  of  adjusting  plate/shim 

in slot on mitered edge of top trim (see 

Figure 6).

5.  Slide  other  end  of  adjusting  plate/shim 

in slot on mitered edge of side trim (see 

Figure 6).

6.  While firmly holding edges of trim to-

gether,  tighten  both  set  screws  on  the 

adjusting plate with slotted screwdriver.

7.  Repeat steps 1 through 6 for other side.

8.  Tighten trim hanging screws (#10 x 6.25 

shoulder) into holes in cabinets. Place 

the assembled trim onto fireplace cabinet. 

Align hanging notches on trim with hang

-

ing screws on side of fireplace (see Figure 

7).  Push  trim  firmly  into  place,  sliding 

hanging notches over hanging screws.

Summary of Contents for FSF32NRWS

Page 1: ...ycallyourgassupplierfromaneighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a quali fi...

Page 2: ...es air oxygen from the room in which it is installed Provisions for adequate combustion and ventilation air must be provided Refer to Air for Combustion and Ven tilation section on page 6 of this manu...

Page 3: ...r flame patterns Ceiling fans can create drafts that alter burner flame patterns Altered burner patterns can cause sooting Due to high temperatures the appliance should be located out oftrafficandaway...

Page 4: ...en Figure 1 Log Base Assembly Top Outer Casing Figure 2 Fireplace Log Set Base Assembly Front Burner Depletion Sensing ODS safety shutoff system The ODS shuts down the fire place if enough fresh air i...

Page 5: ...ews Push the bottom corners of the screen in and release The screen will pop out at the bottom Grasp the bottom of the screen lift the screen up and pull out to remove 3 Remove protective packaging ap...

Page 6: ...stall fireplace plus any adjoining rooms with door less passageways or ventilation grills between the rooms 1 Determine the volume of the space length x width x height Length x Width x Height ________...

Page 7: ...e additional fresh air Your options are as follows A Rework worksheet adding the space of an adjoining room If the extra space provides an unconfined space remove door to adjoining room or add ventila...

Page 8: ...r Inlet Air Inlet Air Ventilated Crawl Space To Crawl Space To Attic Ventilation Air From Outdoors Provide extra fresh air by using ventilation grills or ducts You must provide two perma nent openings...

Page 9: ...luded with the fireplace is to be used it must be wired to a 120 volt supply by a certified electrician OPTIONAL PANELS Each fireplace is shipped with louvered panels installed Smooth panels are also...

Page 10: ...page 14 9 Route blower electrical cord through ac cess holes in either side of fireplace CONVENTIONAL FIREPLACE INSTALLATION Conventional installation of this fireplace involves installing fireplace...

Page 11: ...15 INSTALLATION Continued Figure 12 Inserting Fireplace Into Cabinet Mantel BUILT IN FIREPLACE INSTALLATION Built in installation of this fireplace involves installing fireplace into a framed in encl...

Page 12: ...facing WARNING Do not allow any combustiblematerialstooverlap the firebox front facing IMPORTANT Noncombustible materials such as brick tile etc may overlap the front facing but should never cover an...

Page 13: ...r sleet CAUTION Use only new black iron or steel pipe Inter nally tinned copper tubing may be used in certain areas Check your local codes Use pipe of 1 2 diameter or greater to allow proper gas volum...

Page 14: ...alled or is installed wrong fireplace may not run properly INSTALLATION Continued Figure 17 External Regulator on Propane LP Supply Tank with Vent Pointing Down External Regulator Propane LP Supply Ta...

Page 15: ...flexible gas line is provided to allow accessibility fromthefireplace seeFigure20 The flexible gas supply line con nection to the equipment shutoff valve should be accessible CHECKING GAS CONNECTIONS...

Page 16: ...or Propane LP Gas Propane LP Supply Tank Figure 22 Checking Gas Joints for Natural Gas Gas Control Valve Equipment Shutoff Valve Equipment Shutoff Valve Gas Meter Gas Control Valve Open Closed Equipme...

Page 17: ...ck side of this log needs to rest against the front of the base assembly Make sure the flame from the ember pan does not touch the ember bed log 5 The left middle log has a groove on the bottom to sit...

Page 18: ...sections of chassis assembly as shown in Figure 31 9 Place the left top log onto the rear log and the left middle log Make sure to place the projection on the bottom of the left top log into the reces...

Page 19: ...g the ember chunk in place when it is placed over a shoulder screw Place the ember chunks as shown in Fig ure 35 on page 20 by placing the ember chunk with the number 1 on the left 2 in the center and...

Page 20: ...Chunk 1 Ember Chunk 2 Ember Chunk 3 Flat Front Burner Figure 38 Installing Fireplace Screen Magnets Screen Bracket 4 Installfireplacescreenbyplacingthescreen brackets on top of the fireplace screen br...

Page 21: ...the appliance and to replace any part of the control system and any gas control which has been under water LIGHTING INSTRUCTIONS WARNING Youmustoperate this fireplace with the fireplace screen in pla...

Page 22: ...on or gas supplier for repairs Note If pilot goes out repeat steps 4 through 8 beginning on page 21 9 Slightly push in and turn control knob coun terclockwise to the ON position 10 Move ON OFF selecto...

Page 23: ...r fireplace could pro duce increased levels of carbon monoxide Follow instructions below Yellow flame on rear burner is normal NOTICE Do not mistake orange flames with yellow tipping Dirt or other fin...

Page 24: ...tydamage BURNER INJECTOR HOLDER AND PILOT AIR INLET HOLE The primary air inlet holes allow the proper amount of air to mix with the gas This provides a clean burning flame Keep these holes clear of du...

Page 25: ...en in stalled 5 Depleted gas supply pro pane LP only 6 ODS pilot is clogged 7 Gas regulator setting is not correct REMEDY 1 Reconnect ignitor cable 2 Free ignitor cable if pinched by any metal or tubi...

Page 26: ...intenance page24 or replace burner orifice s 1 Clean burner see Cleaning and Maintenance page 24 or replace burner orifice s 2 Replace damaged burner 3 Replace gas regulator 1 Check burner for dirt an...

Page 27: ...cts 1 Replace 9 volt batteries in receiver and remote control 1 Read EMBER PLACE MENT and correct per in structions 2 Replace orifice Call techni cal service 3 Check burner s for dirt and debris If fo...

Page 28: ...ntenance page 24 1 Locate and correct all leaks see Checking Gas Con nections page 15 2 Replace control valve or gas control 1 Take apart gas tubing and remove foreign matter 2 Locate and correct all...

Page 29: ...ping Weight 122 lbs For input adjustment REPLACEMENT PARTS Note Use only original replacement parts This will protect your warranty coverage for parts replaced under warranty Contact authorized dealer...

Page 30: ...363 01B 30 PARTS LOG BASE ASSEMBLY MODELS FSF32NRWS FSF32PRWS FSF36NRRS AND FSF36PRRS See page 32 for part numbers 1 2 3 5 29 30 4 7 40 13 21 27 11 10 14 16 15 24 12 36 18 37 38 17 39 35 31 20 32 33 1...

Page 31: ...81 06 Valve Gas LP 0 820 642 1 15 103784 01 Knob Short Extension Pilot 1 16 103784 02 Knob Short Extension HI LO 1 17 107634 01SA Plate NG Conversion 1 18 111435 04 Ignitor Electronic 1 19 112465 01 B...

Page 32: ...1 101004 10 Orifice 0453 1 15MM Middle 1 37 111819 10 Orifice Elbow P53 95 110 Pan 1 099056 45 Orifice 0 028 0 711MM Pan 1 111819 11 Orifice Elbow P53 95 300 Pan 1 38 124933 01 Orifice Holder 90 Degre...

Page 33: ...e Smooth 2 2 108423 02 Panel Face Top 32 Stamped 2 106684 01 Panel Closure Top Louvered 36 2 3 110037 01 Electrical Duct Assembly 1 4 20280 Spacer Top 4 5 21171 Cover Gas Conduit Plate 5 6 126366 01 A...

Page 34: ...1 06 125852 06 Log Left Middle 1 7 125851 07 125852 07 Log Right Middle 1 8 125851 08 125852 08 Log Rear Middle 1 9 125851 09 125852 09 Log Rear 1 10 125851 10 125851 10 Log Left Top 1 11 125851 11 12...

Page 35: ...finished mantel or wall open ing edges etc NOTICE All accessories may not be available for all fireplace models Purchase these fireplace accessories from your local dealer If they can not supply these...

Page 36: ...s product and or FMI PRODUCTS LLC who will provide original factory replacement parts Failure to use original factory replacement parts voids this warranty Travel handling transportation diagnostic ma...

Reviews: