www.fmiproducts.com
126363-01B
22
TO TURN OFF GAS
TO APPLIANCE
1. Turn control knob clockwise
to
the OFF position.
2. Close equipment shutoff valve (see Figure
21, page 16).
MANUAL LIGHTING
PROCEDURE
1. Follow steps 1 through 6 under
Lighting
Instructions
, page 21.
2. Press control knob and light pilot with
match.
3. Keep control knob pressed in for 30 sec
-
onds after lighting pilot. After 30 seconds,
release control knob. Now follow steps 9
through 11, column 1.
BLOWER
OPERATION
WARNING: This fireplace has
a three-prong, grounded electri
-
cal plug. This plug helps protect
you against electrical shock.
Only connect plug to a properly
grounded, three-prong recep
-
tacle. Do not cut or remove the
grounding prong from this plug.
Figure 40 - Pilot
OPERATION
Continued
Figure 39 - Control Knob and Ignitor
Button Location
7. With control knob pressed in, press and
release ignitor button. This will light pilot. The
pilot is attached to the front burner. If needed,
keep pressing ignitor button until pilot lights.
Note: If pilot does not stay lit, contact a
qualified service person or gas supplier
for repairs. Until repairs are made, light
pilot with match. To light pilot with match,
see Manual Lighting Procedure.
8. Keep control knob pressed in for 30 sec
-
onds after lighting pilot. After 30 seconds,
release control knob.
• If control knob does not pop out when
released, contact a qualified service
person or gas supplier for repairs.
Note: If pilot goes out, repeat steps 4
through 8 beginning on page 21.
9. Slightly push in and turn control knob coun-
terclockwise
to the ON position.
10. Move ON/OFF selector switch to ON posi
-
tion.
11. Wait one minute to light burners.
12. Set flame adjustment knob to any level
between HI and LO.
13. To leave pilot lit and shut off burners only:
turn control knob clockwise
to the
PILOT position, or use remote control
manual OFF button, or set selector switch
in the OFF position.
WARNING: Make sure the
selector switch is in the OFF
position when you are away from
home for long periods of time.
Heater will come on automati-
cally with selector switch in the
ON position.
Pilot Burner
Ignitor
Electrode
Access the blower control knob by pushing in
on the bottom corners of the fireplace screen,
grasp the bottom of the screen and pull out
and up to remove the screen. The blower
control knob is located on the left side of the
fireplace floor.
The blower is thermostatically controlled. This
means the fireplace and blower will not turn
on and off at the same time. The fireplace
may run for several minutes before the blower
turns on. After the fireplace is shut off, the
blower will continue to operate until the fire
-
place temperature cools.
The blower also includes a variable speed
control. Turn the knob clockwise to turn the
blower to the high position. Continuing to turn
the knob will reduce the speed of the blower
until it reaches a preset low speed.
O
FF
PILOT
LO
IH
AUTO
OFF
ON
ON
Ignitor
Button
Flame Adjustment
Knob
Control Knob