background image

www.fmiproducts.com

126363-01B

22

TO TURN OFF GAS 

TO APPLIANCE

1.  Turn  control  knob  clockwise 

 to 

the OFF position.

2.  Close equipment shutoff valve (see Figure 

21, page 16).

MANUAL LIGHTING 

PROCEDURE

1.  Follow steps 1 through 6 under 

Lighting 

Instructions

, page 21.

2.  Press  control  knob  and  light  pilot  with 

match.

3.  Keep control knob pressed in for 30 sec

-

onds after lighting pilot. After 30 seconds, 

release control knob. Now follow steps 9 

through 11, column 1.

BLOWER

 

OPERATION

 WARNING: This fireplace has 

a three-prong, grounded electri

-

cal plug. This plug helps protect 

you  against  electrical  shock. 

Only connect plug to a properly 

grounded,  three-prong  recep

-

tacle. Do not cut or remove the 

grounding prong from this plug.

Figure 40 - Pilot

OPERATION

Continued

Figure 39 - Control Knob and Ignitor 

Button Location

7.  With control knob pressed in, press and 

release ignitor button. This will light pilot. The 

pilot is attached to the front burner. If needed, 

keep pressing ignitor button until pilot lights.

 

Note: If pilot does not stay lit, contact a 

qualified service person or gas supplier 

for repairs. Until repairs are made, light 

pilot with match. To light pilot with match, 

see Manual Lighting Procedure.

8.  Keep control knob pressed in for 30 sec

-

onds after lighting pilot. After 30 seconds, 

release control knob.

• If control knob does not pop out when 

released,  contact  a  qualified  service 

person or gas supplier for repairs.

 

Note: If pilot goes out, repeat steps 4 

through 8 beginning on page 21.

9.  Slightly push in and turn control knob coun-

terclockwise 

 to the ON position.

10. Move ON/OFF selector switch to ON posi

-

tion.

11. Wait one minute to light burners.

12. Set flame adjustment knob to any level 

between HI and LO.

13. To leave pilot lit and shut off burners only: 

turn control knob clockwise 

 to the 

PILOT  position,  or  use  remote  control 

manual OFF button, or set selector switch 

in the OFF position.

 WARNING: Make sure the 

selector switch is in the OFF 

position when you are away from 

home for long periods of time. 

Heater will come on automati-

cally with selector switch in the 

ON position.

Pilot Burner

Ignitor 

Electrode

Access the blower control knob by pushing in 

on the bottom corners of the fireplace screen, 

grasp the bottom of the screen and pull out 

and  up  to  remove  the  screen. The  blower 

control knob is located on the left side of the 

fireplace floor.

The blower is thermostatically controlled. This 

means the fireplace and blower will not turn 

on  and  off  at  the  same  time. The  fireplace 

may run for several minutes before the blower 

turns  on. After  the  fireplace  is  shut  off,  the 

blower will continue to operate until the fire

-

place temperature cools.

The  blower  also  includes  a  variable  speed 

control. Turn the knob clockwise to turn the 

blower to the high position. Continuing to turn 

the knob will reduce the speed of the blower 

until it reaches a preset low speed.

O

FF

   

PILOT   

LO

 

IH 

AUTO

OFF

ON

ON

     

       

    

Ignitor 

Button

Flame Adjustment 

Knob

Control Knob

Summary of Contents for FSF32NRWS

Page 1: ...ycallyourgassupplierfromaneighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a quali fi...

Page 2: ...es air oxygen from the room in which it is installed Provisions for adequate combustion and ventilation air must be provided Refer to Air for Combustion and Ven tilation section on page 6 of this manu...

Page 3: ...r flame patterns Ceiling fans can create drafts that alter burner flame patterns Altered burner patterns can cause sooting Due to high temperatures the appliance should be located out oftrafficandaway...

Page 4: ...en Figure 1 Log Base Assembly Top Outer Casing Figure 2 Fireplace Log Set Base Assembly Front Burner Depletion Sensing ODS safety shutoff system The ODS shuts down the fire place if enough fresh air i...

Page 5: ...ews Push the bottom corners of the screen in and release The screen will pop out at the bottom Grasp the bottom of the screen lift the screen up and pull out to remove 3 Remove protective packaging ap...

Page 6: ...stall fireplace plus any adjoining rooms with door less passageways or ventilation grills between the rooms 1 Determine the volume of the space length x width x height Length x Width x Height ________...

Page 7: ...e additional fresh air Your options are as follows A Rework worksheet adding the space of an adjoining room If the extra space provides an unconfined space remove door to adjoining room or add ventila...

Page 8: ...r Inlet Air Inlet Air Ventilated Crawl Space To Crawl Space To Attic Ventilation Air From Outdoors Provide extra fresh air by using ventilation grills or ducts You must provide two perma nent openings...

Page 9: ...luded with the fireplace is to be used it must be wired to a 120 volt supply by a certified electrician OPTIONAL PANELS Each fireplace is shipped with louvered panels installed Smooth panels are also...

Page 10: ...page 14 9 Route blower electrical cord through ac cess holes in either side of fireplace CONVENTIONAL FIREPLACE INSTALLATION Conventional installation of this fireplace involves installing fireplace...

Page 11: ...15 INSTALLATION Continued Figure 12 Inserting Fireplace Into Cabinet Mantel BUILT IN FIREPLACE INSTALLATION Built in installation of this fireplace involves installing fireplace into a framed in encl...

Page 12: ...facing WARNING Do not allow any combustiblematerialstooverlap the firebox front facing IMPORTANT Noncombustible materials such as brick tile etc may overlap the front facing but should never cover an...

Page 13: ...r sleet CAUTION Use only new black iron or steel pipe Inter nally tinned copper tubing may be used in certain areas Check your local codes Use pipe of 1 2 diameter or greater to allow proper gas volum...

Page 14: ...alled or is installed wrong fireplace may not run properly INSTALLATION Continued Figure 17 External Regulator on Propane LP Supply Tank with Vent Pointing Down External Regulator Propane LP Supply Ta...

Page 15: ...flexible gas line is provided to allow accessibility fromthefireplace seeFigure20 The flexible gas supply line con nection to the equipment shutoff valve should be accessible CHECKING GAS CONNECTIONS...

Page 16: ...or Propane LP Gas Propane LP Supply Tank Figure 22 Checking Gas Joints for Natural Gas Gas Control Valve Equipment Shutoff Valve Equipment Shutoff Valve Gas Meter Gas Control Valve Open Closed Equipme...

Page 17: ...ck side of this log needs to rest against the front of the base assembly Make sure the flame from the ember pan does not touch the ember bed log 5 The left middle log has a groove on the bottom to sit...

Page 18: ...sections of chassis assembly as shown in Figure 31 9 Place the left top log onto the rear log and the left middle log Make sure to place the projection on the bottom of the left top log into the reces...

Page 19: ...g the ember chunk in place when it is placed over a shoulder screw Place the ember chunks as shown in Fig ure 35 on page 20 by placing the ember chunk with the number 1 on the left 2 in the center and...

Page 20: ...Chunk 1 Ember Chunk 2 Ember Chunk 3 Flat Front Burner Figure 38 Installing Fireplace Screen Magnets Screen Bracket 4 Installfireplacescreenbyplacingthescreen brackets on top of the fireplace screen br...

Page 21: ...the appliance and to replace any part of the control system and any gas control which has been under water LIGHTING INSTRUCTIONS WARNING Youmustoperate this fireplace with the fireplace screen in pla...

Page 22: ...on or gas supplier for repairs Note If pilot goes out repeat steps 4 through 8 beginning on page 21 9 Slightly push in and turn control knob coun terclockwise to the ON position 10 Move ON OFF selecto...

Page 23: ...r fireplace could pro duce increased levels of carbon monoxide Follow instructions below Yellow flame on rear burner is normal NOTICE Do not mistake orange flames with yellow tipping Dirt or other fin...

Page 24: ...tydamage BURNER INJECTOR HOLDER AND PILOT AIR INLET HOLE The primary air inlet holes allow the proper amount of air to mix with the gas This provides a clean burning flame Keep these holes clear of du...

Page 25: ...en in stalled 5 Depleted gas supply pro pane LP only 6 ODS pilot is clogged 7 Gas regulator setting is not correct REMEDY 1 Reconnect ignitor cable 2 Free ignitor cable if pinched by any metal or tubi...

Page 26: ...intenance page24 or replace burner orifice s 1 Clean burner see Cleaning and Maintenance page 24 or replace burner orifice s 2 Replace damaged burner 3 Replace gas regulator 1 Check burner for dirt an...

Page 27: ...cts 1 Replace 9 volt batteries in receiver and remote control 1 Read EMBER PLACE MENT and correct per in structions 2 Replace orifice Call techni cal service 3 Check burner s for dirt and debris If fo...

Page 28: ...ntenance page 24 1 Locate and correct all leaks see Checking Gas Con nections page 15 2 Replace control valve or gas control 1 Take apart gas tubing and remove foreign matter 2 Locate and correct all...

Page 29: ...ping Weight 122 lbs For input adjustment REPLACEMENT PARTS Note Use only original replacement parts This will protect your warranty coverage for parts replaced under warranty Contact authorized dealer...

Page 30: ...363 01B 30 PARTS LOG BASE ASSEMBLY MODELS FSF32NRWS FSF32PRWS FSF36NRRS AND FSF36PRRS See page 32 for part numbers 1 2 3 5 29 30 4 7 40 13 21 27 11 10 14 16 15 24 12 36 18 37 38 17 39 35 31 20 32 33 1...

Page 31: ...81 06 Valve Gas LP 0 820 642 1 15 103784 01 Knob Short Extension Pilot 1 16 103784 02 Knob Short Extension HI LO 1 17 107634 01SA Plate NG Conversion 1 18 111435 04 Ignitor Electronic 1 19 112465 01 B...

Page 32: ...1 101004 10 Orifice 0453 1 15MM Middle 1 37 111819 10 Orifice Elbow P53 95 110 Pan 1 099056 45 Orifice 0 028 0 711MM Pan 1 111819 11 Orifice Elbow P53 95 300 Pan 1 38 124933 01 Orifice Holder 90 Degre...

Page 33: ...e Smooth 2 2 108423 02 Panel Face Top 32 Stamped 2 106684 01 Panel Closure Top Louvered 36 2 3 110037 01 Electrical Duct Assembly 1 4 20280 Spacer Top 4 5 21171 Cover Gas Conduit Plate 5 6 126366 01 A...

Page 34: ...1 06 125852 06 Log Left Middle 1 7 125851 07 125852 07 Log Right Middle 1 8 125851 08 125852 08 Log Rear Middle 1 9 125851 09 125852 09 Log Rear 1 10 125851 10 125851 10 Log Left Top 1 11 125851 11 12...

Page 35: ...finished mantel or wall open ing edges etc NOTICE All accessories may not be available for all fireplace models Purchase these fireplace accessories from your local dealer If they can not supply these...

Page 36: ...s product and or FMI PRODUCTS LLC who will provide original factory replacement parts Failure to use original factory replacement parts voids this warranty Travel handling transportation diagnostic ma...

Reviews: