SAFETY

TABLE OF CONTENTS

Safety .................................................................. 2

Product Identification

 ........................................... 4

Local Codes......................................................... 5

Unpacking............................................................ 5

Product Features ................................................. 5

Air For Combustion and Ventilation ..................... 6

Installation ........................................................... 8

Operation ........................................................... 21

Inspecting Burners............................................. 23

Cleaning and Maintenance ................................ 24

Troubleshooting ................................................. 25

Wiring Diagram .................................................. 29

Specifications

 .................................................... 29

Replacement Parts ............................................ 29

Service Hints ..................................................... 29

Technical Service............................................... 29

Parts .................................................................. 30

Accessories ....................................................... 35

Warranty ..............................................Back Cover

 

WARNING:  Improper 

installation,  adjustment, 

alteration, service, or 

maintenance can cause 

injury  or  property  dam

-

age. Refer to this manual 

for correct installation 

and  operational  proce

-

dures. For assistance or 

additional information 

consult  a  qualified  in

-

staller, service agency, or 

the gas supplier.

 

WARNING: This is an 

unvented  gas-fired  heat

-

er.  It  uses  air  (oxygen) 

from the room in which 

it is installed. Provisions 

for adequate combustion 

and ventilation air must 

be provided. Refer to 

Air 

for Combustion and Ven-

tilation

 section on page 6 

of this manual.

This appliance may be in

-

stalled in an aftermarket,* 

permanently  located, 

manufactured  (mobile) 

home, where not prohib

-

ited by local codes.
This appliance is only for 

use with the type of gas 

indicated  on  the  rating 

plate.  This  appliance  is 

not  convertible  for  use 

with other gases.

* Aftermarket: Completion of sale, not for 

purpose of resale, from the manufacturer

  WARNING:  This  product 

contains  and/or  generates 

chemicals known to the State 

of California to cause cancer or 

birth defects, or other reproduc

-

tive harm.

IMPORTANT: Read this owner’s 

manual carefully and completely 

before trying to assemble, op

-

erate,  or  service  this  heater. 

Improper use of this heater can 

cause  serious  injury  or  death 

from  burns,  fire,  explosion, 

electrical  shock,  and  carbon 

monoxide poisoning.

Summary of Contents for FSF32NRWS

Page 1: ...ycallyourgassupplierfromaneighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a quali fi...

Page 2: ...es air oxygen from the room in which it is installed Provisions for adequate combustion and ventilation air must be provided Refer to Air for Combustion and Ven tilation section on page 6 of this manu...

Page 3: ...r flame patterns Ceiling fans can create drafts that alter burner flame patterns Altered burner patterns can cause sooting Due to high temperatures the appliance should be located out oftrafficandaway...

Page 4: ...en Figure 1 Log Base Assembly Top Outer Casing Figure 2 Fireplace Log Set Base Assembly Front Burner Depletion Sensing ODS safety shutoff system The ODS shuts down the fire place if enough fresh air i...

Page 5: ...ews Push the bottom corners of the screen in and release The screen will pop out at the bottom Grasp the bottom of the screen lift the screen up and pull out to remove 3 Remove protective packaging ap...

Page 6: ...stall fireplace plus any adjoining rooms with door less passageways or ventilation grills between the rooms 1 Determine the volume of the space length x width x height Length x Width x Height ________...

Page 7: ...e additional fresh air Your options are as follows A Rework worksheet adding the space of an adjoining room If the extra space provides an unconfined space remove door to adjoining room or add ventila...

Page 8: ...r Inlet Air Inlet Air Ventilated Crawl Space To Crawl Space To Attic Ventilation Air From Outdoors Provide extra fresh air by using ventilation grills or ducts You must provide two perma nent openings...

Page 9: ...luded with the fireplace is to be used it must be wired to a 120 volt supply by a certified electrician OPTIONAL PANELS Each fireplace is shipped with louvered panels installed Smooth panels are also...

Page 10: ...page 14 9 Route blower electrical cord through ac cess holes in either side of fireplace CONVENTIONAL FIREPLACE INSTALLATION Conventional installation of this fireplace involves installing fireplace...

Page 11: ...15 INSTALLATION Continued Figure 12 Inserting Fireplace Into Cabinet Mantel BUILT IN FIREPLACE INSTALLATION Built in installation of this fireplace involves installing fireplace into a framed in encl...

Page 12: ...facing WARNING Do not allow any combustiblematerialstooverlap the firebox front facing IMPORTANT Noncombustible materials such as brick tile etc may overlap the front facing but should never cover an...

Page 13: ...r sleet CAUTION Use only new black iron or steel pipe Inter nally tinned copper tubing may be used in certain areas Check your local codes Use pipe of 1 2 diameter or greater to allow proper gas volum...

Page 14: ...alled or is installed wrong fireplace may not run properly INSTALLATION Continued Figure 17 External Regulator on Propane LP Supply Tank with Vent Pointing Down External Regulator Propane LP Supply Ta...

Page 15: ...flexible gas line is provided to allow accessibility fromthefireplace seeFigure20 The flexible gas supply line con nection to the equipment shutoff valve should be accessible CHECKING GAS CONNECTIONS...

Page 16: ...or Propane LP Gas Propane LP Supply Tank Figure 22 Checking Gas Joints for Natural Gas Gas Control Valve Equipment Shutoff Valve Equipment Shutoff Valve Gas Meter Gas Control Valve Open Closed Equipme...

Page 17: ...ck side of this log needs to rest against the front of the base assembly Make sure the flame from the ember pan does not touch the ember bed log 5 The left middle log has a groove on the bottom to sit...

Page 18: ...sections of chassis assembly as shown in Figure 31 9 Place the left top log onto the rear log and the left middle log Make sure to place the projection on the bottom of the left top log into the reces...

Page 19: ...g the ember chunk in place when it is placed over a shoulder screw Place the ember chunks as shown in Fig ure 35 on page 20 by placing the ember chunk with the number 1 on the left 2 in the center and...

Page 20: ...Chunk 1 Ember Chunk 2 Ember Chunk 3 Flat Front Burner Figure 38 Installing Fireplace Screen Magnets Screen Bracket 4 Installfireplacescreenbyplacingthescreen brackets on top of the fireplace screen br...

Page 21: ...the appliance and to replace any part of the control system and any gas control which has been under water LIGHTING INSTRUCTIONS WARNING Youmustoperate this fireplace with the fireplace screen in pla...

Page 22: ...on or gas supplier for repairs Note If pilot goes out repeat steps 4 through 8 beginning on page 21 9 Slightly push in and turn control knob coun terclockwise to the ON position 10 Move ON OFF selecto...

Page 23: ...r fireplace could pro duce increased levels of carbon monoxide Follow instructions below Yellow flame on rear burner is normal NOTICE Do not mistake orange flames with yellow tipping Dirt or other fin...

Page 24: ...tydamage BURNER INJECTOR HOLDER AND PILOT AIR INLET HOLE The primary air inlet holes allow the proper amount of air to mix with the gas This provides a clean burning flame Keep these holes clear of du...

Page 25: ...en in stalled 5 Depleted gas supply pro pane LP only 6 ODS pilot is clogged 7 Gas regulator setting is not correct REMEDY 1 Reconnect ignitor cable 2 Free ignitor cable if pinched by any metal or tubi...

Page 26: ...intenance page24 or replace burner orifice s 1 Clean burner see Cleaning and Maintenance page 24 or replace burner orifice s 2 Replace damaged burner 3 Replace gas regulator 1 Check burner for dirt an...

Page 27: ...cts 1 Replace 9 volt batteries in receiver and remote control 1 Read EMBER PLACE MENT and correct per in structions 2 Replace orifice Call techni cal service 3 Check burner s for dirt and debris If fo...

Page 28: ...ntenance page 24 1 Locate and correct all leaks see Checking Gas Con nections page 15 2 Replace control valve or gas control 1 Take apart gas tubing and remove foreign matter 2 Locate and correct all...

Page 29: ...ping Weight 122 lbs For input adjustment REPLACEMENT PARTS Note Use only original replacement parts This will protect your warranty coverage for parts replaced under warranty Contact authorized dealer...

Page 30: ...363 01B 30 PARTS LOG BASE ASSEMBLY MODELS FSF32NRWS FSF32PRWS FSF36NRRS AND FSF36PRRS See page 32 for part numbers 1 2 3 5 29 30 4 7 40 13 21 27 11 10 14 16 15 24 12 36 18 37 38 17 39 35 31 20 32 33 1...

Page 31: ...81 06 Valve Gas LP 0 820 642 1 15 103784 01 Knob Short Extension Pilot 1 16 103784 02 Knob Short Extension HI LO 1 17 107634 01SA Plate NG Conversion 1 18 111435 04 Ignitor Electronic 1 19 112465 01 B...

Page 32: ...1 101004 10 Orifice 0453 1 15MM Middle 1 37 111819 10 Orifice Elbow P53 95 110 Pan 1 099056 45 Orifice 0 028 0 711MM Pan 1 111819 11 Orifice Elbow P53 95 300 Pan 1 38 124933 01 Orifice Holder 90 Degre...

Page 33: ...e Smooth 2 2 108423 02 Panel Face Top 32 Stamped 2 106684 01 Panel Closure Top Louvered 36 2 3 110037 01 Electrical Duct Assembly 1 4 20280 Spacer Top 4 5 21171 Cover Gas Conduit Plate 5 6 126366 01 A...

Page 34: ...1 06 125852 06 Log Left Middle 1 7 125851 07 125852 07 Log Right Middle 1 8 125851 08 125852 08 Log Rear Middle 1 9 125851 09 125852 09 Log Rear 1 10 125851 10 125851 10 Log Left Top 1 11 125851 11 12...

Page 35: ...finished mantel or wall open ing edges etc NOTICE All accessories may not be available for all fireplace models Purchase these fireplace accessories from your local dealer If they can not supply these...

Page 36: ...s product and or FMI PRODUCTS LLC who will provide original factory replacement parts Failure to use original factory replacement parts voids this warranty Travel handling transportation diagnostic ma...

Reviews: