Introduction to the PureFire Technology 

Congratulations!  You  have  purchased  a  “State-of-the-Art”  EPA  Phase  II  Qualified  Emission  Control 
Device for wood burning Fireplaces. 
 
The  PureFire™  Emission  Control  Technology  from  FMI  Products  LLC  is  a  catalytic  system  designed 
especially  for  wood  burning  fireplaces.  PureFire™  utilizes  a  patented  smoke  hood  to  capture  the 
pollutants  from  the  fire  allowing  most  of  the  dilution  air  to  bypass  the  hood  and  exit  through  the 
primary  flue  system.    The  PureFire™  Catalytic  Combustor  provides  secondary  ignition  for  the  wood 
smoke combustibles preventing them from leaving the firebox as particulate pollution. The direct flame 
on the catalytic surface actually cleans the catalytic unit. 
 

The 

PureFire™  Hood

  is  manufactured  from  high  quality  stainless  steel.  The  catalytic  component  is  a 

state-of-the-art ceramic material designed to operate in the direct flame of a fireplace. 

 The 

PureFire™ Unit 

is equipped with mounting hardware to install the hood assembly into the fireplace.  

The mounting hardware is designed with a “Hook Shaped” bracket that attaches to the damper opening.  
The attachment brackets will suspend the PureFire™ above the grate.  

 

 

The PureFire™ Installation

 

The PureFire™ Wood Burning Fireplace Emission 
Control  System  is  positioned  directly  above  the 
grate against the back of the firebox.  

The  damper  handle  for  masonry  fireplaces  will 
extend downward in the center of the PureFire™ 
device.  When  PureFire  is  properly  installed,  the 
fireplace  damper  remains  fully  operational.  The 
opening  between  the  PureFire™  Combustor 
blocks  will  allow  the  damper  handle  to  move 
freely “back-and-forth”.  

 

…………………

CAUTION

………………… 

The damper must be in the open position at all times when the fireplace is in use.  

Never burn a fire with the damper closed! 

 

Maintenance & Catalyst Replacement 

The  PureFire™  Wood  Burning  Fireplace  System  does  NOT  require  any  maintenance.    It  utilizes  a  “self-
cleaning”  catalytic  component.    The  only  time  you  should  remove  the  catalytic  component  is  for 
replacement purposes. There are four (4) screws holding the catalytic block in the PureFire™ hood.  Once 
the  screws  are  removed,  the  catalytic  block  is  easily  removed.  New  screws  are  provided  with  the 
replacement catalyst.  

 

Summary of Contents for AH3143P

Page 1: ...tallation Operating Manual PureFire Wood Burning Fireplace Retro Fit Device For Masonry Factory Built Fireplaces P N AH3143P Revised 8 August 2012 FMI Products LLC 2701 South Harbor Blvd Santa Ana CA 92704 ...

Page 2: ... install the hood assembly into the fireplace The mounting hardware is designed with a Hook Shaped bracket that attaches to the damper opening The attachment brackets will suspend the PureFire above the grate The PureFire Installation The PureFire Wood Burning Fireplace Emission Control System is positioned directly above the grate against the back of the firebox The damper handle for masonry fire...

Page 3: ...ts can be used to identify location of the mounting screw holes A black felt tip can be used to mark the location for drilling There will be two holes drilled on each side of the firebox The firebrick is easily drilled with a 3 16 factory built carbide drill bit Drill the holes to a depth of 1 A suitable hand tool should be used to attach the brackets to the sides of firebox Insure that the bracke...

Page 4: ...n garbage or other foreign materials Avoid artificial logs colored newspaper or petroleum based fire starters Avoid wood with high salt content All of these materials may contain compounds which can shorten the life of the catalyst Wet or unseasoned wood may lower catalytic temperatures and result in inefficient operation The catalyst is designed to function at optimum efficiency when the fireplac...

Page 5: ...ire is equipped with 2 sets of mounting brackets to attach the hood assembly onto the wall of the firebox The flat brackets are designed for factory built fireplaces while the other brackets should be used on factory built metal box fireplaces The mounting hardware is designed with a lip on the front to prevent the PureFire from moving The attachment brackets will suspend the PureFire above the gr...

Page 6: ...should malfunction it must be returned to the factory for evaluation FMI s Customer Service Department will issue an Authorized Return AR number immediately upon phone or written request Upon examination by FMI if the unit is still under warranty and found to be defective it will be repaired or replaced at no charge Warranty Disclaimer FMI s WARRANTY does not apply to defects resulting from any ac...

Reviews: