Section III - Dynamic Displays
20
MN06065 Rev. 0.3 (8/97)
08 - Meter Factor
The current meter factor of the product requested
being used to correct the raw volume to the gross
volume will be displayed.
Meter Factor = 1.0376
09 - Temperature Correction
The current correction for temperature on liquid
factor being used to correct the gross volume to the
gross @ standard temperature volume of the prod-
uct requested will be displayed.
CTL = 0.9927
10 - Correction for Pressure on Liquid
The current correction factor being used to correct
the Gst (Gross @ Standard Temperature) volume to
a net volume based on the current pressure of the
product requested will be displayed.
CPL = 1.0110
11 - Raw Non-resettable Volumes
The raw non-resettable volume for the product re-
quested will be displayed.
Raw Total 000009709
12 - Gross Non-resettable Volumes
The gross non-resettable volume for the product re-
quested will be displayed.
Grs Total 000009002
13 - Gross @ Standard Temperature Non-
resettable Volumes
The gross @ standard temperature non-resettable
volume for the product requested will be displayed.
Gst Total 000008875
14 - Net Non-resettable Volumes
The net non-resettable volume for the product re-
quested will be displayed.
Net Total 000008388
15 - Mass Non-resettable Totals
The mass non-resettable total for the product re-
quested will be displayed.
Mas Total 000053007
16 - Load Average Temperature
The load average temperature of the product re-
quested for the current transaction will be displayed.
Load Avg Temp + 75.0
°
F
17 - Load Average Pressure
The load average pressure of the product requested
for the current transaction will be displayed.
Ld Avg Pres 43.0 Psi