WS009598B
5. Check that the impeller can rotate freely.
WARNING: Crush Hazard
Beware of the pinch point hazard between the rotating impeller and the
guide pin.
6. Adjust the impeller:
a) Turn the adjustment screw clockwise until the impeller touches the pump housing.
7. Fasten the impeller:
a) Fit the lubricated impeller screw.
b) Tighten the impeller screw.
For tightening torque, see
on page 37.
Prevent the impeller from rotating. Insert a screwdriver or similar through the pump
housing outlet.
WS009502A
c) Tighten the screw a further 1/8 turn (45°).
d) Check that the impeller can rotate freely.
e) Check that the impeller moves freely up and down by pushing on it.
When the sleeve is released, it should be fully pushed out again. If the sleeve does
not move freely, or does not come fully out, then replace the impeller unit.
8. Check with a feeler gauge that the impeller clearance is 0.1 – 0.6 mm (0.004–0.02 in).