4.2.6.1 Colors and markings of leads
772 17 00 (REV 7)
COLOUR STANDARD
BN=Brown
BK=Black
WH=White
OG=Orange
GN=Green
GN/YE=Green-Yellow
RD=Red
GY=Grey
BU=Blue
YE=Yellow
STATOR LEADS
U1,U5 RD
U2,U6 GN
V1,V5 BN
V2,V6 BU
W1,W5 YE
W2,W6 BK
T1,T2 WH/YE
*SUBCAB AWG
* * Ground Conductor is stranded around cores
GC=Ground Check
Colours and marking of main leads
Motor connection
1
L1
BK 1
BN
RD
BN
2
L2
BK 2
BK
BK
BK
3
L3
BK 3
GY
WH
GY
L1
BK 4
-
-
-
L2
BK 5
-
-
-
L3
BK 6
-
-
-
GN/YE
GN/YE
GN/YE
**Screen/PE
from cores
Screen (WH) Screen (WH)
-
Screen (WH)
Mains
1~ 3~
SUBCAB 7GX
Screenflex 7GX
SUBCAB 4GX
Screenflex 4GX
SUBCAB AWG
SUBCAB
Screened
GC
-
-
YE
-
WS004125C
Figure 7: 3–phase and 1–phase without built-in starter
For markings on sensor leads, see
4.2.6.2 Connections included
•
on page 27
•
on page 30
•
on page 31
•
4.2.6.3 3-phase connection
3 PHASE
3 Leads
GC
*YE
L1 L2 L3
U1 V1 W1
U1
U1
V1
V1
W1
W1
U2
U2
V2
V2
W2
W2
GN/YE
WH
L3
L2
L1
V1
W1
U1
WS009162A