3 Product Description
Products included
Pump
D-hydraulic
F-hydraulic
M-hydraulic
(Grinder)
N-hydraulic,
cast iron
N-hydraulic,
Hard-Iron
™
N-hydraulic,
stainless steel
3069.060
MT, SH
3069.070
1
MT, SH
3069.090
1
LT, MT, HT
LT
3069.160
MT, SH
3069.170
HT
3069.180
LT, MT, HT
LT
3069.190
1
MT, SH
3069.760
MT, SH
3069.770
1
MT, SH
3069.890
1
HT
1
Explosion proof drive unit
Pump-specific information
For the specific weight, current, voltage, power ratings, and speed of the pump, see the
data plate of the pump.
3.1 Pump design
The pump is submersible, and driven by an electric motor. For motor data, see
on page 58.
Intended use
The product is intended for moving waste water, sludge, raw and clean water. Always
follow the limits given in
on page 58. If there is a question regarding
the intended use of the equipment, please contact a local sales and service representative
before proceeding.
DANGER: Explosion/Fire Hazard
Special rules apply to installations in explosive or flammable atmospheres. Do not install
the product or any auxiliary equipment in an explosive zone unless it is rated explosion-
proof or intrinsically-safe. If the product is rated explosion-proof or intrinsically-safe, then
see the specific explosion-proof information in the safety chapter before taking any
further actions.
Corrosive liquids
NOTICE:
Do NOT use the unit in highly corrosive liquids.
Pressure classes
LT
Low head
MT
Medium head
HT
High head
SH
Super high head
3 Product Description
12
Flygt 3069 Installation, Operation, and Maintenance Manual
Summary of Contents for Flygt 3069
Page 1: ...Installation Operation and Maintenance Manual 885842_10 0 Flygt 3069...
Page 2: ......
Page 55: ...WS009599A 6 Maintenance Flygt 3069 Installation Operation and Maintenance Manual 53...
Page 62: ......
Page 63: ......