To increase accuracy in the fuel flow measurement you must
calibrate the transducer by following this steps.
NOTE:
it's recommended to perform the calibration right after
installing the Remote module and repeat it once a year.
1-
With the aircraft in level attitude, fill the tank/s of fuel; note
that in the step #4 it's required to refill the tank/s at the
exact level reached here.
2-
Turn-on the Vigilus and select “
FILLED
” when asked for
the fuel quantity.
3-
Burn at least 3/4 of fuel in the tank/s: a greater amount of
burned fuel will increase the accuracy, and you can do
this step in more flights: at the start of each flights you
must not add fuel in the tank/s and you must select “
NO
REFUEL
” when asked after turning on the Vigilus.
4-
Fill the tank/s with the exact same level reached in the
step #1, accurately measuring the quantity of fuel added
in the tank/s.
5-
Turn on the Vigilus and select “
NO REFUEL
” (even
though you have refilled it’s required to select “
NO
REFUEL
”).
6-
Enter in the Main menu → Settings → Fuel Computer →
Calibration; the following screen will appears:
1.4 FUEL FLOW TRANSDUCER CALIBRATION
Instrument configuration
Summary of Contents for Vigilus
Page 1: ...Revision 1 0 18 7 2017 For firmware version 2 14 Flybox Operating manual ...
Page 2: ...Page intentionally left blank ...
Page 3: ...SECTIONS INSTRUMENT CONFIGURATION OPERATING INSTRUCTIONS TECHNICAL SPECIFICATIONS ...
Page 10: ...Page intentionally left blank ...
Page 89: ...Page intentionally left blank ...
Page 90: ...Page intentionally left blank ...
Page 91: ...Page intentionally left blank ...