Omnia57
Fuel Comp
-
Installation and User Manual,
Safety Instructions and Warning Booklet
FLYBOX
Rev. 1.0
®
31
Instrument settings
Act delay:
Select a delay in seconds before the alarm is
triggered. When the Low or the High thresholds are
reached, the alarm output will be activated after the set
time. This option can be useful to avoid continuous alarms
when the fuel pressure is stationary at values close to the
set threshold.
Default = 0s
Min = 0s (faster)
Max = 10s (slower)
The alarm is only triggered if the Warning parameter is set
to "Yes". The alarm event triggers both the flashing
message on the screen and the alarm output. Both can be
reset by pressing the knob but the rectangle behind
number remains in red.
After resetting with the knob
Before resetting