Instrument settings
4.5.1 K-Factor Calibration
NOTE:
it's recommended to perform the calibration right after
installing the instrument.
1-
With the aircraft in level attitude, fill the tank/s of fuel; note
that in the step #4 it's required to refill the tank/s at the exact
level reached here.
2-
Turn-on the instrument and select “
FILLED
” when asked for
the fuel quantity.
3-
Burn at least 1/2 of fuel in the tank/s: a greater amount of
burned fuel will increase the accuracy, and you can do this step
in more flights: at the beginning of each flight you must not add
fuel in the tank/s and you must select “
NO REFUEL
” when
asked after turning on the instrument.
4-
Fill the tank/s with the exact same level reached in the step
#1, accurately measuring the quantity of fuel added in the tank/s.
5-
Turn on
Omnia57 Fuel Comp
and select “
NO REFUEL
”
(even though you have refilled it’s required to select “
NO
REFUEL
”).
6-
Select K-Fact Calibration, the following screen will appear: