Original Operating Instructions Eccentric worm drive pump F 550 and Sanitary Pump F 560
33/68
ENGLI
SH
> When using compressed air motors please do not exceed the maximum operating pres-
sure of 6 bars and use filter-regulator-lubricator unit.
> Check direction of rotation of the motor. In case of portable use, check the direction of
rotation again (direction of rotation according to the arrow on the bearing flange).
> The direction of rotation is not prescribed at the horizontal version.
> Mount the horizontal version of the pump completely in the system.
> Clean bearing flange and motor flange. Fit the motor onto the bearing flange and tighten
the screws.
> Check the seat of the motor.
> Make sure the the connection between pump and motor are tightened firmly.
>
Insert the plug or connect the compressed air hose.
>
Switch on the motor.
5.
Internal transport
Attention!
Empty pump, hose and fittings before transport. Completely open
the fittings for emptying.
The plug must be pulled out for transport and the power cable must
be rolled up.
Remove pump from the container for transport. In no way the pump
must be moved with the container.
Equip the pump with an appropriate device so that it cannot fall.
6.
Cleaning
The intensity and the time intervals of the cleaning depend on the requirements on the me-
dium to be pumped. For intensive cleaning the motor has to be dismantled and the pump
has to be disassembled.
Attention!
Only clean pump, motor and mains connection outside the hazard-
ous area.
Centering at the
bearing flange
Motor
Direction of
rotation arrow
Bearing flange
4 screws with hexagonal
recessed hole