4. Adjust flushing time:
Since the closet is Incomplete flushing , please refer to the chart to adjust the appropriate flush time
and obtain an optimum flushing effect.
(Adjust only if necessary)
SW1
SW2
SW3
FLUSH TIME
OFF
OFF
OFF
1 SEC
OFF
OFF
ON
2 SEC
OFF
ON
OFF
3 SEC
OFF
ON
ON
4 SEC
ON
OFF
OFF
5 SEC
Factory setting
ON
OFF
ON
6 SEC
ON
ON
OFF
7 SEC
ON
ON
ON
8 SEC
Cautions
Prior to installation. Make certain the code on the solenoid valve
matches the code on sensor unit. If not, do as follows:
Step1: Find the code matching tool for matching numbers. Press the tool on the specification
tag on the solenoid valve for 1 second. Listen for "BEEP".
Step2: Press the manual button within 5 seconds right after step 1. Then the numbers will be
automatically reset.
Code-matching tool
Beep
Ti e d
1
2
3
O
S 1 S 2 S 3
10