TS25D Test Set

Users Guide

Factory Settings

You can reset the TS25D Test Set to its original factory 
settings. If you do this, the factory settings will be 
restored and the entries in your phonebook and the 
phone numbers in the Call Lists will be deleted. If you 
don’t want to erase the phonebook entries, don’t reset 
to defaults. 

To reset the test set to its factory default settings:

1

Set the slide switch to the Talk (

T

) or Monitor (

M

position.

2

Press the 

SEL

 key.

3

Select the 

SETTINGS

 screen and

 

highlight

 SYSTEM 

CONFIGURATION 

with the arrow keys and press 

the 

SEL

 key.

4

Use the Down arrow key to scroll down to 

FACTORY RESET

 and then press the 

SEL

 key.

5

The screen will display 

PRESS LNR TO RESTORE 

FACTORY SETTINGS

. If you are sure you want to 

restore the factory default settings then press the 

LNR

 key. If you do not want to restore the factory 

settings, press the 

BACK

 key.

Maintenance



Warning

To avoid electric shock, do not perform any 
servicing other than that contained in the 
operating instructions unless you are 
qualified to do so.

Disconnect clips from any metallic 
connections before performing any 
maintenance. 

Caution

Do not use CRC Cable Clean

®

 or any similar 

chlorinated solvent on the test set. Doing so 
will damage the test set.

If moisture should get inside the test set, let the test set 
dry at normal room temperature for 24 hours. DO NOT 
HEAT THE TEST SET. Moisture can provide a leakage 
path that may conduct hazardous voltages to you. DO 
NOT USE the test set if wet.

Keypad Care

Daily use of your test set results in various liquids, dirt, 
and other foreign material building up in your keypad. 
The keypad may be cleaned by using a soft toothbrush 
with soap and water. Do not use a petroleum-based or 
chlorinated cleaning agent as it will harm the keypad. 
Let the test set dry before use.

Replacing the Battery

Caution

Handling batteries should be done with 
care. Do not allow the terminals to be 
shorted together. Dispose of battery 
properly to ensure contacts cannot short. 
Disposal may be restricted by local laws.

To replace the battery (see Figure 3):

1

Turn the test set off. 

2

Place the test set on a work surface, face down. 
The work surface should be non-abrasive.

3

Using a Phillips screwdriver, remove the single 
cover screw attaching the battery door cover to 
the back of the test set.

4

Remove the battery door cover and the old 9 V 
battery from the test set. Properly discard the 
battery.

5

Insert a new 9 V battery. Make sure the polarity is 
correct.

Note

Do not over tighten screw. Over tightening will 
strip the plastic.

Summary of Contents for TS 25D

Page 1: ...TS 25D Test Set PN 2451820 October 2005 Rev 3 3 13 2005 2009 2012 2013 Fluke Corporation All rights reserved Printed in China All product names are trademarks of their respective companies Users Guide...

Page 2: ...or replacement of a defective product which is returned to a Fluke Networks authorized service center within the warranty period To obtain warranty service contact your nearest Fluke Networks authori...

Page 3: ...des and Functions 6 Monitor Mode 6 Talk Mode 6 Data Lockout 6 Data Lockout Override 7 High Voltage Lockout 7 Low Voltage Lockout 8 Talk Battery 8 Caller ID Call Waiting ID 9 Toner 9 DTMF Detection 10...

Page 4: ...Pause Duration 14 Flash Duration 14 System Timeout 15 Speaker Timeout 15 Data Lockout 15 Firmware Version 15 Factory Settings 16 Maintenance 16 Keypad Care 16 Replacing the Battery 16 Replacing the L...

Page 5: ...ccess to valuable information on product updates troubleshooting tips and other support services To register fill out the online registration form on the Fluke Networks website at www flukenetworks co...

Page 6: ...Flash Memory Dialing Tone and Pulse Dialing Displays Voltage when on hook Displays Current when off hook Polarity Indication Detect and Display Caller ID Call Waiting ID CIDCW Toner Talk Battery DTMF...

Page 7: ...ric keypad is used to dial telephone numbers and make function selections The keypad includes 12 standard dialing keys the asterisk key and pound key SPKR The SPKR speaker key turns the speaker on inc...

Page 8: ...of the test set The line cord included with the standard TS25D Test Set has angled bed of nails clips The line cord included with the TS25D CO Test Set has a 346A plug Extension line cords for the 346...

Page 9: ...the line is not powered Battery The battery icon indicates the battery s charge level The battery level is continuously displayed in Monitor and Talk mode On off hook The telephone icon tells you if...

Page 10: ...e test set will go off hook and draw dial tone An off hook TS25D test Set works like a standard telephone When off hook the test set is used to perform its main purpose which is to verify the proper o...

Page 11: ...ARROW TO OVERRIDE Now if you want to go off hook to access the analog phone service sharing the line with ADSL press the down arrow as instructed on the LCD The test set will override the lockout wil...

Page 12: ...oned When the test set connected to a line carrying data signals but no DC voltage is switched to Talk mode the LCD will display DATA DETECTED AND LOW VOLT LOCKOUT Some data services have no associate...

Page 13: ...or arrange for someone to call the line the test set is connected to When the call comes in you will hear the Call Waiting Alert tone This will be followed by the CAS tone and the Caller ID message W...

Page 14: ...ck to Monitor mode DTMF detection is only available when the TS25D Test Set is in Monitor mode Call and Dialing Functions Note Remove the protective film that covers the LCD display before using your...

Page 15: ...erisk and pound keys are pressed in Pulse mode they will be ignored Memory Dialing The TS25D Test Set allows the user to dial pre programmed numbers in either Tone or Pulse mode If dialing in Pulse mo...

Page 16: ...slash quote period or 1 depending on how many times you press the key Use the Up arrow to erase characters In this case the Up arrow moves the cursor to the left 7 After the entry is complete press th...

Page 17: ...rsor location A comma is used to represent a pause Pauses are used to put time delays into a string of numbers The default pause duration is 4 seconds 10 After the entry is complete press the SEL key...

Page 18: ...screen see Figure 2 Timing Use the Timing option to set the Pause duration and the Flash duration Pause Duration To set the Pause duration 1 Set the slide switch to the Talk T or Monitor M position 2...

Page 19: ...ss the SEL key or press 3 on the keypad 3 Press 2 SPKR TIMEOUT 4 Highlight the desired time with the arrow keys then press the SEL key or press one of the following keys on the keypad 1 2 minutes TS25...

Page 20: ...imilar chlorinated solvent on the test set Doing so will damage the test set If moisture should get inside the test set let the test set dry at normal room temperature for 24 hours DO NOT HEAT THE TES...

Page 21: ...r 5 Loosen the two screws that hold the line cords to the PCB 6 Using needle nose pliers or one of the line cord clips remove the two screws and washers from the line cord connectors 7 Position the sc...

Page 22: ...last number redial memory Digit Capacity 23 digits per memory Pause Duration User programmable Default 4 seconds Hook Flash Duration User programmable Default 600 ms Automatic Speaker Shut Off Durati...

Reviews: