background image

12

TS25D Test Set

Users Guide

Memory Programming

Each memory location will store a phone number up to 
23 digits in length. If you enter more than 23 digits only 
the first 23 will be remembered.

To store a new phone number:

1

Set the slide switch to the Talk (

T

) or Monitor (

M

position.

2

Press the 

SEL

 key. 

3

When the Main menu is displayed, highlight 

EDIT 

PHONEBOOK

 with the arrow keys, then press the 

SEL

 key. The list of phonebook entries is displayed. 

When you scroll through the entries, the number 
in the upper right of the screen indicates which 
one of the 10 memory locations you have selected. 
If you have no phonebook entries or if you are 
viewing this screen for the first time, it will be 
blank.

4

Select an empty memory location (0 through 9) 
with the arrow keys then press the 

SEL

 key, or use 

the number keys. A list of phonebook editing 
options appears.

5

Highlight 

EDIT NAME 

and press the 

SEL

 key. 

6

The screen will change to 

NAME

. Enter the name 

you want to assign to this Phonebook entry using 
the test set’s keypad. Example: The 

key gives you 

four possible characters: 

A

B

C

, and 

2

. If you press 

the 

key once, the letter 

A

 is entered at the 

cursor’s location. If you rapidly press the 

key 

three times, the letter 

C

 is entered. If you rapidly 

press the 

key four times, the number 

2

 is 

entered. After entering the desired character, wait 
a moment for the cursor to move one space to the 
right then enter the next character. Enter the 
remaining characters in the same manner. The 
asterisk key (

) provides a space on the first press 

and an asterisk on the second press. The 

1

 key 

provides 

&

, dash (

-

), forward slash (

/

), quote (

), 

period (

.

), or 

depending on how many times you 

press the key.

 

Use the Up arrow to erase 

characters. In this case, the Up arrow moves the 
cursor to the left.

7

After the entry is complete, press the 

SEL 

key to 

save the entry and return to the list of editing 
options.

8

Highlight 

EDIT NUMBER

 and press the 

SEL

 key 

or press the 

2

 key.

9

The screen will change to 

NUMBER

. Enter the 

phone number using the test set’s keypad. This 
time pressing a dialing key will cause the number 
on the key to be entered. Use the Up arrow to 
erase characters. In this case, the Up arrow moves 
the cursor to the left.

On the 

Number

 screen, the 

FLSH

 key changes its 

normal meaning and becomes the 

PAUSE

 key. As 

you enter numbers into memory, if you press the 

FLSH

 key, a pause is entered at the cursor location. 

A comma is used to represent a pause. Pauses are 
used to put time delays into a string of numbers. 
The default pause duration is 4 seconds.

10

After the entry is complete, press the 

SEL 

key to 

save the entry and return to the list of editing 
options.

11

Press the 

BACK

 key twice to return to the Main 

menu, or press it three times to return to the main 
operating screen.

To edit an existing stored number:

1

Switch the test set to Talk (

T

) or Monitor (

M

) mode.

2

Press the 

SEL

 key.

3

When the Main menu is displayed, highlight 

EDIT 

PHONEBOOK

 with the arrow keys, then press the 

SEL

 key. The list of phonebook entries is 

displayed. When you scroll through the entries, 
the number in the upper right of the screen 
indicates which one of the 10 memory locations 
you have selected. Pressing the arrow keys lets you 
scroll through all locations (0 through 9).

4

Move the cursor to the memory location you wish 
to edit and press the 

SEL

 key.

5

If you want to edit the name in the phonebook, 
highlight 

-

 EDIT NAME

 and press the 

SEL

 key.

Summary of Contents for TS 25D

Page 1: ...TS 25D Test Set PN 2451820 October 2005 Rev 3 3 13 2005 2009 2012 2013 Fluke Corporation All rights reserved Printed in China All product names are trademarks of their respective companies Users Guide...

Page 2: ...or replacement of a defective product which is returned to a Fluke Networks authorized service center within the warranty period To obtain warranty service contact your nearest Fluke Networks authori...

Page 3: ...des and Functions 6 Monitor Mode 6 Talk Mode 6 Data Lockout 6 Data Lockout Override 7 High Voltage Lockout 7 Low Voltage Lockout 8 Talk Battery 8 Caller ID Call Waiting ID 9 Toner 9 DTMF Detection 10...

Page 4: ...Pause Duration 14 Flash Duration 14 System Timeout 15 Speaker Timeout 15 Data Lockout 15 Firmware Version 15 Factory Settings 16 Maintenance 16 Keypad Care 16 Replacing the Battery 16 Replacing the L...

Page 5: ...ccess to valuable information on product updates troubleshooting tips and other support services To register fill out the online registration form on the Fluke Networks website at www flukenetworks co...

Page 6: ...Flash Memory Dialing Tone and Pulse Dialing Displays Voltage when on hook Displays Current when off hook Polarity Indication Detect and Display Caller ID Call Waiting ID CIDCW Toner Talk Battery DTMF...

Page 7: ...ric keypad is used to dial telephone numbers and make function selections The keypad includes 12 standard dialing keys the asterisk key and pound key SPKR The SPKR speaker key turns the speaker on inc...

Page 8: ...of the test set The line cord included with the standard TS25D Test Set has angled bed of nails clips The line cord included with the TS25D CO Test Set has a 346A plug Extension line cords for the 346...

Page 9: ...the line is not powered Battery The battery icon indicates the battery s charge level The battery level is continuously displayed in Monitor and Talk mode On off hook The telephone icon tells you if...

Page 10: ...e test set will go off hook and draw dial tone An off hook TS25D test Set works like a standard telephone When off hook the test set is used to perform its main purpose which is to verify the proper o...

Page 11: ...ARROW TO OVERRIDE Now if you want to go off hook to access the analog phone service sharing the line with ADSL press the down arrow as instructed on the LCD The test set will override the lockout wil...

Page 12: ...oned When the test set connected to a line carrying data signals but no DC voltage is switched to Talk mode the LCD will display DATA DETECTED AND LOW VOLT LOCKOUT Some data services have no associate...

Page 13: ...or arrange for someone to call the line the test set is connected to When the call comes in you will hear the Call Waiting Alert tone This will be followed by the CAS tone and the Caller ID message W...

Page 14: ...ck to Monitor mode DTMF detection is only available when the TS25D Test Set is in Monitor mode Call and Dialing Functions Note Remove the protective film that covers the LCD display before using your...

Page 15: ...erisk and pound keys are pressed in Pulse mode they will be ignored Memory Dialing The TS25D Test Set allows the user to dial pre programmed numbers in either Tone or Pulse mode If dialing in Pulse mo...

Page 16: ...slash quote period or 1 depending on how many times you press the key Use the Up arrow to erase characters In this case the Up arrow moves the cursor to the left 7 After the entry is complete press th...

Page 17: ...rsor location A comma is used to represent a pause Pauses are used to put time delays into a string of numbers The default pause duration is 4 seconds 10 After the entry is complete press the SEL key...

Page 18: ...screen see Figure 2 Timing Use the Timing option to set the Pause duration and the Flash duration Pause Duration To set the Pause duration 1 Set the slide switch to the Talk T or Monitor M position 2...

Page 19: ...ss the SEL key or press 3 on the keypad 3 Press 2 SPKR TIMEOUT 4 Highlight the desired time with the arrow keys then press the SEL key or press one of the following keys on the keypad 1 2 minutes TS25...

Page 20: ...imilar chlorinated solvent on the test set Doing so will damage the test set If moisture should get inside the test set let the test set dry at normal room temperature for 24 hours DO NOT HEAT THE TES...

Page 21: ...r 5 Loosen the two screws that hold the line cords to the PCB 6 Using needle nose pliers or one of the line cord clips remove the two screws and washers from the line cord connectors 7 Position the sc...

Page 22: ...last number redial memory Digit Capacity 23 digits per memory Pause Duration User programmable Default 4 seconds Hook Flash Duration User programmable Default 600 ms Automatic Speaker Shut Off Durati...