Ti32, TiR32
Users Manual
20
Total Imager Range
Span
Le
v
el
exj02.eps
Figure 2. Range and Span Settings
5.
To exit the manual level and span adjustment, squeeze and release the
trigger quickly twice in order to return to live view.
The Imager remains at this Level until it is manually adjusted again or the
Imager is returned to auto mode.
Note
The scale along the right side of the screen display indicates the
range.
Setting the Temperature Span (Manual)
When put into manual ranging, the span setting adjusts the palette over a
temperature range within the total range of the Imager. See Figure 2. To adjust
the temperature span:
1.
After entering the manual range mode (see “Setting the Range”), press the
softkey labeled
Go to Span
. This will place the Imager into the
Adjusting Span
mode.
2.
Press the softkey labeled
Increase
to widen the temperature span or
Decrease
to narrow it.
Summary of Contents for Ti32