Ti90, Ti95, Ti100, Ti105, Ti110, Ti125, TiR105, TiR110, TiR125
Users Manual
36
5. Push
or
to view the menu.
6. Push
/
to highlight
Palette
.
7. Push
or
to view the menu.
8. Push
/
to highlight
Standard
or
Ultra Contrast
.
9. Push
/
to select a palette.
10. Push:
•
to set the change and go back to the live view.
•
or
to set the change and go back to the previous menu.
•
to cancel the change and go back to the live view.
IR-Fusion
®
IR-Fusion
®
makes it easier to understand infrared images through the use of an
aligned visible image and infrared image. The Imager automatically captures a
visible image with every infrared image to show you exactly what you see and
then allows you to more effectively show it to others.
IR-Fusion has different modes that vary by model, see Table 8. Full Visible
mode is also available. (The Fluke Ti100 does not have IR-Fusion and can only
display a full infrared image.)
Table 8. Infrared and IR-Fusion Modes by Model
T
i90
T
i95
T
i100
T
i105
T
i110
T
i125
T
iR105
T
iR110
T
iR125
Full AutoBlend
(min IR mode)
• •
•
•
Full AutoBlend
(mid IR mode)
• • • • •
•
Max IR (Full Thermal)
• • • • • • • •
•
Full Visible
• •
• • • • •
•
Picture-in-Picture AutoBlend
(min)
• •
•
•
Picture-in-Picture AutoBlend
(mid)
• • • • •
•
Picture-in-Picture AutoBlend
(max)
•
• • • • •
•
Note: Ti105 and TiR105 models have aligned IR-Fusion from 1.2 m to 4.6 m (4 ft to 15 ft).