SMFT-1000
Users Manual
26
10. Push
.
11. Push
to hold the ac-L3 measurements.
The blue column header indicates that the ac-L3 measurements are on hold.
The display shows the Efficiency Factor ratio with a Pass or Fail icon.
12. Push
to save the results to memory.
A confirmation message with ID number shows on the display and then returns to the test
screen.
AC/DC Voltage Measurement
Single-shot voltage measurement that automatically detects ac or dc power.
To make a measurement:
1. Turn the rotary switch on the PV Analyzer to
FUNC./P
AC/DC
.
2. Push
to measure the voltage.
The dashes on the display indicate that no leads are connected to the PV Analyzer.
3. Connect the test leads to the circuit under test.
Tip: Push
to see a connection diagram.
The PV Analyzer automatically detects if the measurement is ac or dc voltage.
4. Push
to hold the measurement.
The measurement is on hold.
5. Push
to save the results to memory.
A confirmation message with ID number shows on the display and then returns to the test
screen.
AC/DC Current Measurement
Single-shot current measurement that automatically detects ac or dc power.
To make a measurement:
1. Turn the rotary switch on the PV Analyzer to
FUNC./P
AC/DC
.
2. Toggle
to measure the current.
The
button toggles the selection between a voltage or current measurement. The
dashes on the display indicate that no leads are connected to the PV Analyzer.