5
5.
Press F4 save, and your setup and the screen that was on the scope
will be saved in the location you selected.
C.
Recalling a Setup.
1.
Press the round “Save/Print” button to open the save menu.
2.
Press the F2 Recall button.
3.
Use the up/down arrows to highlight the location (out of 15 choices)
where you saved the setup.
4.
Press F2 Recall Setup button to recall you saved setup.
5.
You will be automatically be brought to a screen w/ your setup.
D.
To capture a series of fencer transients.
1.
Attach you 1:1 probes to the Input A connector.
2.
Turn on the scope.
3.
Connect the probe between the two points of the selected cow contact
location, preferable at close to (in) the location and w/o other wires
attached to the location.
4.
You will have to adjust the trigger level, voltage scale, and time scale
to capture what you want.
a.
Start with the voltage scale set to 1 Volt per division, the time scale
set at 1 second per division, and the trigger set around a couple of
volts. (Use the 1 second per division scale because the fencers
generally put out 1 pulse per second, making it easy to identify that
what you are capturing is a fencer or trainer transient.)
b.
If nothing shows up, open the trigger menu by pressing the
rectangular Trigger button.
1)
Use the up/down arrows to adjust the trigger level until you
get something.
2)
If you still get nothing, change the voltage scale by pushing the
Input A Range button to change the scale to higher or lower
values. Note the scale per division changes in the red box on
the lower left side of the screen.
c.
If the screen is overloaded, with signals appearing off screen,
change the input scale by pushing the Range button to raise the
scale. Raise it until the entire signal appears on the screen.
5.
Press the Clear Menu button to clear the trigger menu, once you are
satisfied w/ your snapshot.
6.
To save the screen, press the Save/Print button, press F1 to open the
save menu, use the up/down arrows to highlight the location you
wish to save the screen, and press save. Press the Clear Menu button
to clear the Save/Print menu. You are now ready to go again.