background image

FLK-TI-SBC3B

Charging Base/Power Supply with Adapters

Instruction Sheet

The Fluke FLK-TI-SBC3B Charging Base/Power Supply with Adapters charges the Fluke 

FLK-TI-SBP3B Smart Battery Pack for Thermal Imagers. The FLK-TI-SBC3B consists of a 

charging base, power supply, and power outlet adapters.

PN 4352179  May 2013
© 2013 Fluke Corporation. All rights reserved. 

All product names are trademarks of their respective companies. Specifications are subject to change without notice. 

 

Safety Information

Use the FLK-TI-SBC3B only as specified in this instruction sheet or other Fluke 

product-specific manual. See Table 1 for a list of symbols used on the FLK-TI-SBC3B.

Warning

 identifies hazardous conditions and procedures that are dangerous to the user. 

Caution

 identifies conditions and procedures that may cause damage to the Product or 

the equipment under test.

W

 Warning

To avoid injury:

 

Do not disassemble or short circuit the battery pack.

 

Do not expose the battery pack to temperatures above 50 °C (122 °F).

 

Do not incinerate or mutilate the battery pack.

 

Use only ac adapters approved by Fluke for the product to charge the battery or 

power the product.

Table 1. Symbols

Symbol

Description

P

Conforms to requirements of European Union and European Free Trade Association.

"

Imager connected to battery charger.

;

Conforms to relevant Australian standards.

)

Conforms to relevant Canadian and US standards

W

Important information. See manual.

~  

This product complies with the WEEE Directive (2002/96/EC) marking requirements. 

The affixed label indicates that you must not discard this electrical/electronic product in 

domestic household waste. Product Category: With reference to the equipment types 

in the WEEE Directive Annex I, this product is classed as category 9 “Monitoring and 

Control Instrumentation” product. Do not dispose of this product as unsorted municipal 

waste. Go to Fluke’s website for recycling information.

Charging the Battery

Before using the battery pack for the first time, charge the battery in the two-bay charging 

base for at least two and one-half hours. For complete charging instructions, see the 

Thermal Imagers User Manual.

Specifications

See Table 2 for the specifications.

Table 2. Specifications

Battery Charging

10-15 Vdc 2 A or charge battery pack in Imager with included ac 

adapter rated: 100-240 Vac 50/60 Hz, 15 V 2 A.

Charging / Power LED

Status

Charging LED

Power LED

off

no battery detected

no dc power input

solid green

charged

dc power present

blinking green

charging

na

blinking red

fault

na

Dimensions

159.5 mm x 68.9 mm x 51.3 mm (6.28 in x 2.71 in x 2.02 in)

Operating Temperature

-10 °C to 70 °C (-14 °F to 158 °F)

Storage Temperature

-20 °C to 80 °C (-4 °F to 176 °F) without batteries

Humidity Range

10 % to 95 % non-condensing

Reviews: