FLK-TI-SBC3B
Charging Base/Power Supply with Adapters
Instruction Sheet
The Fluke FLK-TI-SBC3B Charging Base/Power Supply with Adapters charges the Fluke
FLK-TI-SBP3B Smart Battery Pack for Thermal Imagers. The FLK-TI-SBC3B consists of a
charging base, power supply, and power outlet adapters.
PN 4352179 May 2013
© 2013 Fluke Corporation. All rights reserved.
All product names are trademarks of their respective companies. Specifications are subject to change without notice.
Safety Information
Use the FLK-TI-SBC3B only as specified in this instruction sheet or other Fluke
product-specific manual. See Table 1 for a list of symbols used on the FLK-TI-SBC3B.
A
Warning
identifies hazardous conditions and procedures that are dangerous to the user.
A
Caution
identifies conditions and procedures that may cause damage to the Product or
the equipment under test.
W
Warning
To avoid injury:
●
Do not disassemble or short circuit the battery pack.
●
Do not expose the battery pack to temperatures above 50 °C (122 °F).
●
Do not incinerate or mutilate the battery pack.
●
Use only ac adapters approved by Fluke for the product to charge the battery or
power the product.
Table 1. Symbols
Symbol
Description
P
Conforms to requirements of European Union and European Free Trade Association.
"
Imager connected to battery charger.
;
Conforms to relevant Australian standards.
)
Conforms to relevant Canadian and US standards
W
Important information. See manual.
~
This product complies with the WEEE Directive (2002/96/EC) marking requirements.
The affixed label indicates that you must not discard this electrical/electronic product in
domestic household waste. Product Category: With reference to the equipment types
in the WEEE Directive Annex I, this product is classed as category 9 “Monitoring and
Control Instrumentation” product. Do not dispose of this product as unsorted municipal
waste. Go to Fluke’s website for recycling information.
Charging the Battery
Before using the battery pack for the first time, charge the battery in the two-bay charging
base for at least two and one-half hours. For complete charging instructions, see the
Thermal Imagers User Manual.
Specifications
See Table 2 for the specifications.
Table 2. Specifications
Battery Charging
10-15 Vdc 2 A or charge battery pack in Imager with included ac
adapter rated: 100-240 Vac 50/60 Hz, 15 V 2 A.
Charging / Power LED
Status
Charging LED
Power LED
off
no battery detected
no dc power input
solid green
charged
dc power present
blinking green
charging
na
blinking red
fault
na
Dimensions
159.5 mm x 68.9 mm x 51.3 mm (6.28 in x 2.71 in x 2.02 in)
Operating Temperature
-10 °C to 70 °C (-14 °F to 158 °F)
Storage Temperature
-20 °C to 80 °C (-4 °F to 176 °F) without batteries
Humidity Range