DTX-PCU6S Patch Cord Adapters 

Users Manual 

4

 

Testing Patch Cords 

W

Caution 

Testing patch cords that have poorly crimped plugs may reduce the life of 
the patch cord adapter's jacks. 

Note 

If you want to verify the performance of RJ45 plugs before using them to 
make patch cords, see Appendix B. 

Testing Cat 5e Patch Cords 

While the DTX-PCU6 patch cords adapters are optimized for testing Cat 6 patch cords, 
they may also be used to test Cat 5e patch cords. To test Cat 5e patch cords without 
modifying the adapters, select a Cat 5e cable type and a Cat 6 limit in SETUP. 

To optimize the adapters for testing Cat 5e patch cords, replace the RJ45 jacks in the 
adapters with Cat 5e jacks specially selected for testing patch cords. See "Replacement 
Parts" on page 9 for a source for these jacks. See "Replacing the Adapter's Jacks" on 
page 8 for installation instructions. 

Setting Up the Tester 

1

 

Attach the DTX-PCU6/MN adapter to the main DTX tester. Attach the DTX-PCU6/SR 
adapter to the remote DTX tester. 

2

 

Turn the rotary switch to SETUP; then select Twisted Pair

3

 

On the Twisted Pair menu, select Cable Type

4

 

Select the category of twisted pair cable used for the patch cords, then select the 
appropriate cable type. 

5

 

On the Twisted Pair menu, select Test Limit

6

 

Select the patch cord limit with the appropriate category and length.  

If the appropriate limit is not shown on the Last Used menu, press 

J

 More; then 

select Patch Cords to see more patch cord limits. 

Notes 

If the patch cord's length is not listed in the limits database, select a limit 
with the next longest length. For example, if the patch cord is 2.2 m long, 
select a limit for a 2.5 m patch cord. 

If you are testing Cat 5e patch cords and have not replaced the adapter 
jacks with Cat 5e jacks, select a Cat 6 limit. 

CENELEC limits are preceded by "CLC" in the patch cord limits list. 

Running the Patch Cord Test 

1

 

Connect the patch cord to be tested to the main and remote testers, as shown in 
Figure 1. 

2

 

Turn the rotary switch to Autotest; then press 

P

3

 

To save the results, press 

N

, enter or select a cable ID; then press 

N

 again. 

Summary of Contents for DTX-PCU6S

Page 1: ...DTX PCU6S Patch Cord Adapters Users Manual November 2004 2004 Fluke Corporation All rights reserved All product names are trademarks of their respective companies...

Page 2: ...eturned to a Fluke Networks authorized service center within the warranty period To obtain warranty service contact your nearest Fluke Networks authorized service center to obtain return authorization...

Page 3: ...hy Patch Cords Fail 5 Wire Map Failures 6 Return Loss Failures 6 NEXT Failures 7 Fault Information for Long Patch Cords 7 Mechanical Stress Tests for Patch Cords 8 Replacing the Adapter s Jacks 8 When...

Page 4: ...ii DTX PCU6S Patch Cord Adapters Users Manual...

Page 5: ...1 Replacement Parts 9 C 1 Cat 5e Patch Cord Limits per TIA EIA 568 B C 1 C 2 Cat 6 Patch Cord Limits per TIA EIA 568 B C 2 C 3 Cat 5e Patch Cord Limits per ISO IEC 11801 2002 C 2 C 4 Cat 6 Patch Cord...

Page 6: ...iv DTX PCU6S Patch Cord Adapters Users Manual...

Page 7: ...le Page 1 Patch Cord Test Connections 5 2 Return Los Failures and Low and High Frequencies 7 3 Replacing the RJ45 Jack 9 4 Measurement Accuracy of the DTX PCU6S Patch Cord Test Configuration 10 B 1 Pr...

Page 8: ...vi DTX PCU6S Patch Cord Adapters Users Manual...

Page 9: ...priate standards organization for details Contact Fluke Networks for general information on standards and for DTX software or database updates that may result from changes to standards The patch cord...

Page 10: ...2 539 6311 Singapore 65 6738 5655 Taiwan 886 2 227 83199 USA 1 800 283 5853 Anywhere in the world 1 425 446 4519 Visit our website for a complete list of phone numbers Additional Resources for Cable...

Page 11: ...ware to install new software into the DTX testers See the DTX CableAnalyzer Users Manual the DTX CableAnalyzer Technical Reference Handbook or the online help in LinkWare for instructions Note Patch c...

Page 12: ...ttach the DTX PCU6 SR adapter to the remote DTX tester 2 Turn the rotary switch to SETUP then select Twisted Pair 3 On the Twisted Pair menu select Cable Type 4 Select the category of twisted pair cab...

Page 13: ...Note NEXT loss and return loss are measured in one direction only as required by the patch cord test standard For standard patch cords up to 5 m this method is adequate and can detect performance pro...

Page 14: ...nges in impedance Excessive untwisting of pairs at plug Poor quality plug Cable impedance not uniform poor quality cable Cable compression pinches kinks etc Poorly matched plug and jack most often aff...

Page 15: ...oor quality plug Poor quality cable Poorly matched plug and jack Cat 6 Class E applications Cable compression pinches kinks etc Excessive noise source near cabling under test Use the impulse noise tes...

Page 16: ...s may be worn away however continuous use wipes off the oxidation and extends the life of the contacts WCaution Testing patch cords that have poorly crimped plugs may reduce the life of the patch cord...

Page 17: ...rs performance See Appendix A Insulation displacement connectors in RJ45 jack Connectors on circuit board h bal11f eps Figure 3 Replacing the RJ45 Jack Replacement Parts Table 1 shows the replacement...

Page 18: ...ation The results were computed using the methods defined in standards applicable to field tester requirements The accuracies shown reflect the accuracy of the measurement circuitry excluding variabil...

Page 19: ...erize the adapters and determine if they are working properly DTX PCU6S Performance Test Using a Reference Patch Cord When you first receive your adapters you should test a patch cord and save the cor...

Page 20: ...patch cord go to the correct testers 2 Run an Autotest then save the results 3 Compare the results with the reference patch cord s previous results The difference between the old and new NEXT and RL r...

Page 21: ...patch cord test limit with the shortest length If you are testing Cat 5e plugs and have replaced the adapters jacks with Cat 5e jacks select the Cat 5e limit with the shortest length Run the NEXT and...

Page 22: ...DTX PCU6S Patch Cord Adapters Users Manual B 2...

Page 23: ...e Replacing the Adapter s Jacks on page 8 for installation instructions Table C 1 Cat 5e Patch Cord Limits per TIA EIA 568 B Patch Cord Length and NEXT dB Freq MHz 0 5m 1m 1 5m 2m 2 5m 3m 3 5m 4m 5m 7...

Page 24: ...38 08 37 79 37 64 37 55 37 55 14 0 Note Patch cord performance requirements for CENELEC standards CLC limits are equivalent to those for ISO IEC standards except that CENELEC standards have no requir...

Page 25: ...57 63 57 06 23 4 20 61 60 53 60 11 59 75 59 42 59 12 58 85 58 6 58 17 57 32 56 71 55 88 55 36 23 7 25 59 08 58 62 58 21 57 85 57 53 57 24 56 98 56 74 56 32 55 5 54 92 54 15 53 68 24 0 31 25 57 16 56...

Reviews: