![Fluke CableAnalyzer DSP-4100 User Manual Download Page 86](http://html1.mh-extra.com/html/fluke/cableanalyzer-dsp-4100/cableanalyzer-dsp-4100_user-manual_2309836086.webp)
DSP-4000 Series
Users Manual
3-20
Pressing
#
View Plot
produces the ACR plot screen. Figure 3-8 describes
an example of the screen.
6
5
4
3
2
1
oy12c.eps
1
The cable pairs relevant to the plot.
2
Frequency range in MHz of the ACR test. Use
U
D
to change the frequency scale.
3
The ACR level, frequency, and margin at the cursor’s position. The cursor aligns to the
frequency that produced the worst margin. Margin is the difference between the limit and
measured values plotted at the cursor’s position. Use
L R
to move the cursor left or right.
If you move the cursor beyond the highest test frequency specified by the selected test
standard, the readout shows the ACR value at the cursor’s position.
4
The ACR limits, as defined by the selected test standard. The limit line is dashed at
frequencies where the attenuation is less than 4 dB.
5
Decibels of ACR for the cable pair.
6
The calculated ACR for the cable pairs.
Figure 3-8. The ACR Plot Screen
Summary of Contents for CableAnalyzer DSP-4100
Page 10: ...DSP 4000 Series Users Manual viii...
Page 20: ...DSP 4000 Series Users Manual 1 8...
Page 66: ...DSP 4000 Series Users Manual 2 46...
Page 99: ...Autotest The Autotest Report 3 3 33 oy82f bmp Figure 3 12 Autotest Report in Tabular Format...
Page 138: ...DSP 4000 Series Users Manual 6 6...
Page 170: ...DSP 4000 Series Users Manual 7 32...
Page 195: ...Appendices Appendix Title Page A Tests Supported by LIAs A 1 B Glossary B 1...
Page 196: ......
Page 210: ...DSP 4000 Series Users Manual B 12...
Page 216: ...DSP 4000 Series Users Manual 6...