Autotest
Autotest Results for Twisted Pair Cabling
3
3-15
Pressing
#
View Plot
produces the NEXT plot screen. Figure 3-6
describes an example of the screen.
6
5
4
3
2
1
oy11c.eps
1
The cable pairs relevant to the plot.
2
Frequency range in MHz. Use
U D
to switch between scales. To switch to the next lowest
or highest range, use
L R
to move the cursor beyond the left or right side of the plot.
3
The NEXT level, frequency, and margin at the cursor’s position. The cursor aligns to the
frequency that produced the worst margin. Margin is the difference between the limit and
measured values plotted at the cursor’s position. If you move the cursor beyond the highest
test frequency specified by the selected test standard, the readout shows the NEXT value
at the cursor’s position.
4
The limits for NEXT, as defined by the selected test standard. A crosshair is shown if the
limit is defined for only one frequency. The limit line is dashed at frequencies where the
attenuation is less than 4 dB.
5
Decibels of crosstalk attenuation (NEXT) between the cable pairs.
6
The measured NEXT for the cable pairs.
Figure 3-6. The NEXT Plot Screen
Summary of Contents for CableAnalyzer DSP-4100
Page 10: ...DSP 4000 Series Users Manual viii...
Page 20: ...DSP 4000 Series Users Manual 1 8...
Page 66: ...DSP 4000 Series Users Manual 2 46...
Page 99: ...Autotest The Autotest Report 3 3 33 oy82f bmp Figure 3 12 Autotest Report in Tabular Format...
Page 138: ...DSP 4000 Series Users Manual 6 6...
Page 170: ...DSP 4000 Series Users Manual 7 32...
Page 195: ...Appendices Appendix Title Page A Tests Supported by LIAs A 1 B Glossary B 1...
Page 196: ......
Page 210: ...DSP 4000 Series Users Manual B 12...
Page 216: ...DSP 4000 Series Users Manual 6...