Table 4-3. Effects of Termination on HDTDR Results
Cable Type
and
Termination
Listed Results Show the Following
Plotted Results Show the
Following
Twisted pair
with no
remote
Displays the message
No
Remote
Detected
. Results show the two
largest reflections greater than or equal
to 15%. The largest reflection probably
comes from the end of the cable, but is
not identified as the end.
All reflections are shown.
Twisted pair
with remote
Two largest reflections greater than or
equal to 15%. Largest reflection is
identified as the end of the cable.
All reflections are shown.
Coaxial cable
with no
terminator
Two largest reflections greater than or
equal to 10%. The largest reflection
comes from the end of the cable, but is
not identified as the end.
All reflections are shown. The
largest reflection comes from the
end of the cable.
Coaxial
Cable with
terminator
No Reflection
reported for a
good cable. On a faulty cable, the test
reports the two largest reflections, but
does not identify end of cable.
All reflections are shown. The plot
will not show a reflection from the
terminated end.
Summary of Contents for CableAnalyzer DSP-4100
Page 10: ...DSP 4000 Series Users Manual viii...
Page 20: ...DSP 4000 Series Users Manual 1 8...
Page 66: ...DSP 4000 Series Users Manual 2 46...
Page 99: ...Autotest The Autotest Report 3 3 33 oy82f bmp Figure 3 12 Autotest Report in Tabular Format...
Page 138: ...DSP 4000 Series Users Manual 6 6...
Page 170: ...DSP 4000 Series Users Manual 7 32...
Page 195: ...Appendices Appendix Title Page A Tests Supported by LIAs A 1 B Glossary B 1...
Page 196: ......
Page 210: ...DSP 4000 Series Users Manual B 12...
Page 216: ...DSP 4000 Series Users Manual 6...