Digital Communications Interface
Commands
6
6-15
Response: 0
A value of 1 is returned if a power loss alarm event has occurred. A value of 0 is returned
if a power loss alarm event has not occurred.
ALARm:POWer:ENABle?
Returns the state of the power loss alarm enable.
Example: ALAR:POW:ENAB?
Response: 0
A value of 1 is returned if the power loss alarm is enabled. A value of 0 is returned if the
power loss alarm is disabled.
ALARm:POWer:ENABle <bool>
Sets the state of the power loss alarm enable.
Example: ALAR:POW:ENAB 1
The <bool> parameter turns the power loss alarm on (1 or ON) or off (0 or OFF). This
command may be password protected (see Password Commands).
ALARm:RHUMidity<chn>:LOWer?
Indicates whether a lower humidity alarm event has occurred for the specified channel.
Example: ALAR:RHUM1:LOW?
Response: 0
The RHUMidity suffix, <chn>, specifies the channel (1 or 2). A value of 1 is returned if a
lower humidity alarm event has occurred on the specified channel. A value of 0 is
returned if a lower humidity alarm event has not occurred on the specified channel.
ALARm:RHUMidity<chn>:LOWer:ENABle?
Returns the state of the lower humidity alarm enable for the specified channel.
Example: ALAR:RHUM1:LOW:ENAB?
Response: 0
The RHUMidity suffix, <chn>, specifies the channel (1 or 2). A value of 1 is returned if
the lower humidity alarm is enabled. A value of 0 is returned if the lower humidity alarm
is disabled.
ALARm:RHUMidity<chn>:LOWer:ENABle <bool>
Sets the state of the lower humidity alarm enable for the specified channel.
Example: ALAR:RHUM1:LOW:ENAB 1
The RHUMidity suffix, <chn>, specifies the channel (1 or 2). The <bool> parameter
turns the lower humidity alarm enable on (1 or ON) or off (0 or OFF). This command
may be password protected (see Password Commands).
ALARm:RHUMidity<chn>:LOWer:LIMit? [MIN|MAX|DEF]
Returns the lower humidity alarm limit for the specified channel in %RH.
Example: ALAR:RHUM1:LOW:LIM?
Summary of Contents for 5020A
Page 6: ...5020A Users Manual iv...
Page 8: ...5020A Users Manual vi...
Page 12: ...5020A Users Manual 1 2...
Page 20: ...5020A Users Manual 2 2...
Page 24: ...5020A Users Manual 3 2...
Page 30: ...5020A Users Manual 3 8...
Page 32: ...5020A Users Manual 4 2...
Page 38: ...5020A Users Manual 5 2 Comm Setting 5 30 Serial 5 31 IR 5 32 Password 5 32 System Info 5 34...
Page 72: ...5020A Users Manual 6 2...
Page 124: ...5020A Users Manual 6 54...
Page 126: ...5020A Users Manual 7 2...
Page 130: ...5020A Users Manual 7 6...
Page 132: ...5020A Users Manual 8 2...
Page 138: ...5020A Users Manual 8 8...
Page 141: ...Index continued 3 W warnings 1 4 Z zone types 5 9...
Page 142: ...5020A Users Manual 4...