1587 FC/1587/1577
Users Manual
8
Table 4. Rotary Switch Selections (cont.)
Switch
Position
Measurement Function
158
7 F
C
1
5
87
158
7T
1
5
77
k
Temperature from - 40
°
C to
+
537
°
C (- 40
°
F to
+
998
°
F).
Celsius is the default temperature measurement unit. The temperature measurement you select is
retained in memory when the Meter is turned off.
•
•
•
o
Ohms from 0.1
Ω
to 50 M
Ω
.
•
•
•
•
Capacitance from 1 nF to 9999
μ
F.
•
•
•
X
Continuity test. Beeper turns on at
<
25
Ω
and turns off at
>
100
Ω
.
•
•
•
•
O
Diode test. There is no ranging in this function. Displays
above 6.600 V.
•
•
•
c
AC mA from 3.00 mA to 400 mA (600 mA overload for 2 minutes maximum).
DC mA from 0.01 mA to 400 mA (600 mA overload for 2 minutes maximum).
•
•
•
•
a
INSULATION
Ohms from 0.01 M
Ω
to 2 G
Ω
. The last selected output voltage setting is retained in memory when the
Meter is turned off.
•
•
•
Ohms from 0.01 M
Ω
to 600 M
Ω
. The last selected output voltage setting is retained in memory when the
Meter is turned off.
•
Performs insulation test with:
50 V, 100 V, 250 V, 500 V (default), and 1000 V source
•
•
500 V (default) and 1000 V source
•
50 V (default) and 100 V source
•
Press the blue button to activate smoothing during insulation testing.
•
•
•