Setup variables
PDU
ADDRESS
REGISTER
VARIABLE
TOTAL
NO.
REGISTERS
R/W
TYPE
VALUE / REMARKS
[d] 32
[h] 0x020
40033
unit
1
r/w
uint16 0=none
1=L
2= m
3
3=kg
4= lb
5=gal
6= US GAL
7=bbl
[d] 33
[h] 0x021
40034
decimals
1
r/w
uint16
0…3
[d] 34
[h] 0x022
40035
span
2
r/w
uint32 1...9999999
Representation: 0.000001…9999999
depending on variable 54: decimals span.
[d] 37
[h] 0x025
40038
decimals span
1
r/w
uint16
0…6
PDU
ADDRESS
REGISTER
VARIABLE
FLOW RATE
NO.
REGISTERS
R/W
TYPE
VALUE / REMARKS
[d] 48
[h] 0x030
40049
unit
1
r/w
uint16 0=mL
1=L
2= m
3
3=mg
4=g
5=kg
6=ton
7=GAL
8=bbl
9=lb
10=cf
11=rev
12=none
13=scf
14=NM
3
15=NL
16=p
[d] 49
[h] 0x031
40050
time unit
1
r/w
uint16 0=/sec
1=/min
2=/hour 3=/day
[d] 50
[h] 0x032
40051
decimals
1
r/w
uint16
0…3
[d] 51
[h] 0x033
40052
span
2
r/w
uint32 1...9999999
Representation: 0.000001…9999999
depending on variable 54: decimals span.
[d] 54
[h] 0x036
40055
decimals span
1
r/w
uint16
0…6
PDU
ADDRESS
REGISTER VARIABLE
ALARM
NO.
REGISTERS
R/W
TYPE
VALUE / REMARKS
[d] 70
[h] 0x046
40071
flow zero
1
r/w
uint16 0=ignore
1=default
2=no relay
[d] 234
[h] 0x0EA
40235
alarm value low-low
2
r/w
uint32 0...9999999
[d] 240
[h] 0x0F0
40241
alarm value low
2
r/w
uint32 0...9999999
[d] 243
[h] 0x0F3
40244
alarm value high
2
r/w
uint32 0...9999999
[d] 237
[h] 0x0ED
40238
alarm value high-high
2
r/w
uint32 0...9999999
[d] 205
[h] 0x0CD
40206
delay time value low-low
1
r/w
uint16 0...999.9
[d] 246
[h] 0x0F6
40247
delay time value low
1
r/w
uint16 0...999.9
[d] 248
[h] 0x0F8
40249
delay time value high
1
r/w
uint16 0...999.9
[d] 222
[h] 0x0DE
40223
delay time value high-high
1
r/w
uint16 0...999.9
PDU
ADDRESS
REGISTER
VARIABLE
DISPLAY
NO.
REGISTERS
R/W
TYPE
VALUE / REMARKS
[d] 64
[h] 0x040
40065
display function
1
r/w
uint16 0=total
1=flow rate
[d] 68
[h] 0x044
40069
Alarm set
1
r/w
uint16 0=operate
1=setup
2=hidden
[d] 67
[h] 0x043
40068
backlight brightness
1
r/w
uint16 0=off
1=20%
2=40%
3=60%
4=80%
5=100%
[d] 110
[h] 0x06E
40111
Backlight alarm
1
r/w
uint16 0=off
1=on
2=flash
PDU
ADDRESS
REGISTER
VARIABLE
POWER MANAGEMENT
NO.
REGISTERS
R/W
TYPE
VALUE / REMARKS
[d] 80
[h] 0x050
40081
LCD update time
1
r/w
uint16 0=fast
1=1sec
2=3sec
3=15sec
4=30sec
5=off
[d] 81
[h] 0x051
40082
power mode
1
r/w
uint16 0=operational
1=shelf