Particles Limits
Max Particles Per Display Collage:
This parameter value can be increased or decreased to satisfy user
needs and requirements.
Max Particles to Graph During Capture:
This parameter value can be increased or decreased to
satisfy user needs and requirements.
Max Particles Per List:
This parameter value can be increased or decreased to suit user needs and
requirements.
Accept Full Screen Particles:
This check box will enable the software to capture and accept sample
particles that are of a size that has them contacting one edge of the field of view to a second edge. Note
that the field of view is determined by the acceptable region setting.
Help… Advanced Tools Menu > Advanced Calibration
Calibration Factor (microns per pixel)
- The Calibration Factor is used to convert measurements made
in pixels to microns. The factory determined Default Value, along with the Current Value being used, is
displayed in this window. Fluid Imaging Technologies does not recommend adjusting the factory
determined Calibration Factor. However, the Advanced Calibration function will allow for the use of a
New Calibration Factor. If a new value is entered and the Apply button is selected, a warning will be
displayed to indicate that a critical value is about to be modified. Select Yes to continue or No to cancel.
Help… Advanced Tools Menu > Advanced Timing
The Advanced Timing Settings button will open a new window that contains three subsections
(Recovery Time, Laser Cycle Time, Camera Trigger Duration). In general, the user should not access or
adjust any of these factory set parameters.
Help… Advanced Tools Menu > DSP Monitor
The DSP Monitor window is an advanced area that is for use by Fluid Imaging Technologies trained
personnel. It is not recommended that the FlowCAM user adjust any of these values or settings unless
directly instructed to do so by customer service personnel.
Help… Advanced Tools Menu > Scatter Detector Monitor
The Scatter Detector Monitor window is an advanced area that is for use by Fluid Imaging Technologies
trained personnel. It is not recommended that the FlowCAM user adjust any of these values or settings
unless directly instructed to do so by customer service personnel.
Help… Advanced Tools Menu > Camera Type
The Camera Type window is an advanced area that is for use by Fluid Imaging Technologies trained
personnel. It is not recommended that the FlowCAM user adjust any of these values or settings unless
directly instructed to do so by customer service personnel.