background image

2

IMPORTANT SAFETY PRECAUTIONS & EXPLANATION OF SYMBOLS

• 

Please read this manual thoroughly before attempting to install or 
operate any Fluence SPYDR Series system .

• 

After successful installation and configuration of the system, be sure to 
retain this manual in a safe place for future reference . Safety is a key 
component to a long lasting and trouble-free installation .

 It is important you read, fully understand, and observe the subsequent 

safety precautions . If you are not comfortable with the installation of 
high performance lighting systems, you should seek the services of a 
qualified installation professional or call us for help .

• 

NOTICE: The SPYDR 2x, SPYDR 2p and SPYDR 2i are high-performance 
lighting systems . Do not touch while in operation .

• 

Connect the system only to the power sources of the appropriate voltage 
using the AC plug type received . Protect power cables from being 
pinched, walked on, or otherwise damaged . Be especially careful where 
the power cable enters the power outlet and the unit . Only connect the 
system to an electrical outlet or extension cord of appropriate type and 
rating . Connect the system only to the power sources of the correct 
voltage using the plug received .

• 

DO NOT defeat the safety purpose of a grounding or polarized plug by 
removing ground pins or using unsafe adapters . A polarized plug has 
two blades –one wider than the other . A grounding plug has a third 
ground prong in addition to the two main conductors . The wide blade 
or third grounding prong is provided for your safety . If the provided plug 
foes not fit your outlet, consult an electrician to replace your obsolete 
outlet . If you replace the power cord, only use one of similar type and 
equal or greater current rating . 

 The system should only be cleaned as directed in the manual . You should 

seek service for your system by qualified service personnel if any of the 

following occur:

  1 . The power-supply cord or the plug has been damaged .
  2 . The unit has been exposed to rain .
  3 . The unit exhibits a marked change in performance .
  4 . The unit has been dropped, or its enclosure or chassis is damaged .

CULTIVATION BEST PRACTICES

Fluence encourages everyone to experiment and pursue their own techniques . 
Every crop is different and everyone has different goals . However, our internal 
research has given us insight into several strategies we would like to share .

 Regularly check your plants’ growth and health . Fluence lighting systems 

deliver high levels of PAR, typically more than experienced in nature . 
Adjustments to H2O, CO2, RH, nutrients, and temperature are typically required .

• 

Mount the fixture at least 6” from the top of your canopy to ensure optimal 
uniformity and consistent PPFD . The SPYDR Series was designed to provide 
uniform light dispersion and requires precise deployment . A 1” variation in 
either direction will have a significant change in uniformity and PPFD (which 
may or may not be desired) .

• 

Many plants prefer higher temperatures when exposed to high PPFD . 
Experiment with higher temperatures to achieve higher yields . Canopy 
temperature and room ambient temperature often vary . For accurate results, 
test at the canopy level to gauge leaf surface temperature .

For cultivation recommendations visit 

www.fluence.science/cultivation-guide/

Summary of Contents for SPYDR 2i

Page 1: ...2p SPYDR 2i IMPORTANT SAFETY PRECAUTIONS EXPLANATION OF SYMBOLS 2 BEST PRACTICES 2 GENERAL CARE 3 SYSTEM HARDWARE ACCESSORIES 5 ASSEMBLY INSTRUCTIONS 6 TECHNICAL SPECIFICATIONS 8 CAUTIONS WARNINGS 11 PRODUCT GUARANTEE WARRANTY 12 ...

Page 2: ...ty If the provided plug foes not fit your outlet consult an electrician to replace your obsolete outlet If you replace the power cord only use one of similar type and equal or greater current rating The system should only be cleaned as directed in the manual You should seek service for your system by qualified service personnel if any of the following occur 1 The power supply cord or the plug has ...

Page 3: ...utinely check for and remove excess dust debris and mineral build up from heatsink and LED array Cleaning should always be done with the fixture unplugged from its power source using low pressure compressed air or water to rinse away dirt from light bars Never use a cloth to clean the diode array Doing so can scratch or compromise the integrity of the silicon seal or dislodge diodes entirely To li...

Page 4: ...4 SPYDR 2 SPYDR 2x SPYDR 2p SPYDR 2i ...

Page 5: ...erfall Mount C2 Solid Decking Mount C3 Sloped Decking Mount C4 Lance Hanger C5 Lance Hanger with Adjustable Kit option if upgraded at time of purchase ACCESSORIES D 1 Vinyl cut Fluence Sticker E Power Supply Accessories E1 1 6 AC Power Cord 1 15 AC Power Cord option if upgraded at time of purchase E2 1 3 or 6 DC Extension Cord option if upgraded at time of purchase E3 2 Power Supply Light Bar Brac...

Page 6: ... a surface A Ensure the quick release mechanism on light bar clip is positioned according to diagram before sliding into place The spring tab will lock light bar into place when properly centered i When the module is unfolded and LEDs are facing down against the flush surface attach Power Supply Light Bar Brackets to the center two bars and press firmly until they snap into place SAFTEY NOTE Light...

Page 7: ... the bracket mounts with the bracket receivers iv Reach under the power supply and twist the bracket locks into place v Once the power supply enclosure is installed do not attempt to fold the SPYDR 2 module Doing so will cause significant damage to the fixture B Remote mount To remote mount the power supply refer to the mounting instruction manual ...

Page 8: ... 1 87A Family Model Spectrum Input Voltage AC Power Cord AC Plug DC Extension Cord Mounting Hardware SR SPYDR 2x X I PhysioSpec Indoor 1 100 277V 06 6 0 1 83m N5P NEMA 5 15P 00 None W Waterfall Mounts 2p PLUS 3 347V 15 15 0 4 57m N6P NEMA 6 15P 03 3 91cm S Solid Decking Mounts 2i i 4 400V L7P NEMA L7 15P 06 6 1 83m M 2 Point Hanging Lances 5 480V TFP Schuko Type F M 2 Point Adjustable Hanging Kit ...

Page 9: ... 27lbs 11oz 108 7cm L x 119 4cm W x 10 9cm H 12 55kg 42 8 L x 46 99 W x 4 3 H 27lbs 11oz 108 7cm L x 119 4cm W x 10 9cm H 12 55kg Mounting Height 6 15 2cm Above Canopy 6 15 2cm Above Canopy 6 15 2cm Above Canopy Thermal Management Passive Passive Passive Dimming 0 10V 0 10V 0 10V Light Distribution 120 120 120 Lifetime L90 54 000hrs L90 54 000hrs L90 54 000hrs Power Factor 90 90 90 Certifications ...

Page 10: ...10 46 99 119 4cm 42 8 108 7cm 20 8 52 8cm 3 1 7 9cm 2 4 6 1cm 16 7 42 4cm 21 9 55 6cm 42 8 108 7cm 6 2 15 9cm 1 3 3 2cm 4 3 10 9cm Dimensions ...

Page 11: ...ilation of fixtures and power supplies ETL Rating SPYDR fixtures are rated suitable for wet locations A wet location is defined as an interior or exterior location in which water or other liquids may drip splash or flow on or against the electrical components of a lighting fixture SPYDR Series fixtures and power supply are certified to meet UL standards ETL from the Intertek safety consulting and ...

Page 12: ... date of purchase Contact us at support fluencebioengineering com for information on five year extended warranties We stand behind our research we stand behind our technology and we stand behind our clients www fluence science warranty 512 212 4544 fluence science Copyright 2018 Fluence Bioengineering Inc Version 1 09 2018 71038A Review our products share your grow and stay abreast of the latest F...