background image

To find your local Flowserve representative:

For more information about Flowserve Corporation, visit 
www.flowserve.com or call USA 1 800 225 6989

Flowserve Corporation has established industry leadership in the design and manufacture of its products. When properly selected, this Flowserve product is designed to perform its 

intended function safely during its useful life. However, the purchaser or user of Flowserve products should be aware that Flowserve products might be used in numerous applications 

under a wide variety of industrial service conditions. Although Flowserve can (and often does) provide general guidelines, it cannot provide specific data and warnings for all possible 

applications. The purchaser/user must therefore assume the ultimate responsibility for the proper sizing and selection, installation, operation, and maintenance of Flowserve products. 

The purchaser/user should read and understand the Installation Operation Maintenance (IOM) instructions included with the product, and train its employees and contractors in the safe 

use of Flowserve products in connection with the specific application.

While the information and specifications contained in this literature are believed to be accurate, they are supplied for informative purposes only and should not be considered certified or 

as a guarantee of satisfactory results by reliance thereon. Nothing contained herein is to be construed as a warranty or guarantee, express or implied, regarding any matter with respect 

to this product. Because Flowserve is continually improving and upgrading its product design, the specifications, dimensions and information contained herein are subject to change 

without notice. Should any question arise concerning these provisions, the purchaser/user should contact Flowserve Corporation at any one of its worldwide operations or offices.

© 2006 Flowserve Corporation, Irving, Texas, USA. Flowserve is a registered trademark of Flowserve Corporation.

FCD LGENTB0059-01 10/09  Printed in USA. 

Flowserve Headquarters

5215 N. O’Connor Blvd., Suite 

2300 

Irving, TX 75039

Telephone: 972 443 6500

Control Valve Manufacturing

1350 Mountain Springs Parkway

Springville, UT 84663-3004 USA

Telephone: 1 801 489 8611

Fax: 1 801 489 3719

Singapore

12 Tuas Ave. 20, 638824

Republic of Singapore

Telephone: +65 862 3332

Fax: +65 862 4940

Austria

Kasernengasse 6

Villach Austria 9500

Telephone: +43 0 4242 41181 0

Fax: +43 0 4242 41181 50

Australia

14 Dalmore Dr.

Scoresby, Victoria, Australia 3179

Telephone: +61 3 9759 3300

Fax: +61 3 9759 3301

China

585, Hanwei Plaza

7 Guanghua Road

Beijing, China 100004

Telephone: +86 10 6561 1900

flowserve.com

Summary of Contents for Logix 3000MD Series

Page 1: ...TECHNICAL BULLETIN Logix 3000MD Series Digital Positioner Experience In Motion...

Page 2: ...es at a glance using the highly visible LEDs Users can easily determine if a valve or actuator is functioning properly and quickly diagnose any problems using the smart LED blink codes This means that...

Page 3: ...ration Logix 3000MD Positioner Overview The Logix 3000MD Series Digital Positioner How It Works Tuning Unlike other positioners that have only one set gains to set the response of the positioner the L...

Page 4: ...FISCO Compliant User Interface P Polarity Insensitive UI Potted UI P AO Block 30mS P PID Block 6 PID Equations 90mS P 2 DI Block 20mS P 1 DO Block 30mS P 1 IS Block 50mS P 1 OS Block 50mS P LAS Link...

Page 5: ...bility Tuning P Integral 4 20 mA Feedback Option P Flash RAM Local Positioner Embedded Code Upgrade P Local Valve Signature Storage P Local Calibration and Setup P 24 7 Local Fault Monitoring P Local...

Page 6: ...d device and local validation that setup is correct make any HART installation easy and straightforward With the Logix 3200MD the local interface shown to the right can be used to set up the unit in s...

Page 7: ...ludes pressure sensors and full featured valve diagnostics HART Command 1 3 9 33 48 Burst Mode available to continuously transmit Position command analog loop current Final value of command after char...

Page 8: ...s instantly displayed on the local interface and through the ValveSight DTM software The health bars in the Dashboard view instantly indicate any developing issues and quickly direct the user to the i...

Page 9: ...Custom Units of Measure P P P3 P P P3 P P All Variable Editor P P P P P P P P C alibration Analog Output Calibration P P P P P Analog Input Calibration P P P P P Stroke Calibration P P P P P P P P Pre...

Page 10: ...mmunication active Communications HART Protocol ITK 5 6 Minimum Operating Current 3 6 mA without AO board 3 7 mA with AO board Maximum Voltage 30 0 VDC Table II Environmental Conditions Operating Temp...

Page 11: ...ators 33 B 173298 35 4 173298 6 7 70 10 173298 Valtek Trooper 166636 0 75 1 50 Std Automax R314 141180 HD SNA115 NK313A Vangard 37 64 175128 Air Torque AT Series AT0 AT6 Consult factory Automax SNA Se...

Page 12: ...FS DPOEVJU QPSUT 15 UISFBE PQUJPOBM 4VQQMZ 0VUQVU BOE 0VUQVU QPSUT 15 UISFBE OEJDBUPST BJO PWFS VTUPNFS OUFSGBDF PWFS 4QPPM 7BMWF PWFS BOE 7FOU SJWFS PWFS 4RVBSF PMMPXFS BSN MJNJU JT GSPN QPTJUJPO TIP...

Page 13: ...ally Safe Ex ia IIC T4 Tamb 400 C to 850 C T5 Tamb 400 C to 550 C Ex ia D 20 T950 C 400 C to 800 C ATEX II 1 G D CENELEC GOST GGTN Ex i Intrinsically Safe IIC 15 3400MD IECEx Explosionproof 16 IECEx I...

Page 14: ...80 C IP65 04 or 15 Intrinsically Safe II 1 G Ex ia IIC See Warning No 2 3 Ui 30 Volts Ii 100mA Pi 800mW Ci 30 nF Li 0 Co 36 nF T4 Tamb 40 C to 85 C T5 Tamb 40 C to 55 C IP65 04 Non Incendive II 3 G E...

Page 15: ...I II Div 2 Groups A B C D See Warning No 2 Not Required T4 Tamb 80 C Type 4X ATEX 28 Explosionproof Flameproof II 2 GD Ex d IIB H2 Ex tD A21 T95 C See Warning No 1 2 Not Required T5 T 40 C to 80 C IP...

Page 16: ...be accurate they are supplied for informative purposes only and should not be considered certified or as a guarantee of satisfactory results by reliance thereon Nothing contained herein is to be const...

Reviews: