background image

Logix 3200IQ Digital Positioner  FCD LGENTB0059-01 – 10/09

10

Specifications for Logix 3400MD

Power Supply

Two-wire, 9-32 VDC
FF compatible

IS

Fisco compliant

Communications

FF Protocol ITK 4.6x, 5.0

Operating Current

23 mA

Maximum Voltage

36.0 VDC

Table I: Electrical Specifications

Operating Temperature 

Range

Standard

-40° to 176°F
(-40° to 80°C)

Transport and Storage  

Temperature Range

-40° to 176°F (-40° to 80°C)

Operating Humidity

0 - 100% non-condensing

Note:  The air supply must conform to ISA Standard ISA 7.0.01 (a 

dew point at least 18 degrees Fahrenheit below ambient tempera-

ture, particle size below five microns—one micron recom-

mended—and oil content not to exceed one part per million).

Table II: Environmental Conditions

Deadband

<0.1% full scale

Repeatability

<0.05% full scale

Linearity

<0.5% (rotary), <0.8%, (sliding stem) full scale

Air Consumption <0.3 SCFM (0.5 Nm

3

/hr) @ 60 psi (4 bar)

Air Supply

30-150 psig (ISA 7.0.0.1 compliant)

Air Delivery

12 SCFM @ 60 psi (0.27 Cv)

Table IV: Positioner Specifications

Table I: Electrical Specifications

Power Supply

Two-wire, 4-20 mA
10.0 to 30.0 VDC

Compliance Voltage

10.0 VDC @ 20 mA

Effective Resistance

495 Ω @ 20 mA Typical
Add 20 Ω when HART communication 

active

Communications

HART Protocol ITK 5,6

Minimum Operating 

Current

3.6 mA without AO board
3.7 mA with AO board

Maximum Voltage

30.0 VDC

Table II: Environmental Conditions

Operating Temperature 

Range

Standard

-4° to 176°F
(-20° to 80°C)

Low

-40° to 176°F
(-40° to 80°C)

Transport and Storage  

Temperature Range

-40° to 176°F (-40° to 80°C)

Operating Humidity

0 - 100% non-condensing

Note:  The air supply must conform to ISA Standard ISA 7.0.01 

(a dew point at least 18 degrees Fahrenheit below ambient 

temperature, particle size below five microns—one micron recom-

mended—and oil content not to exceed one part per million).

Table III: Physical Specifications

Housing 

Material

Cast, powder-painted aluminum or stainless steel

Soft Goods

Buna-N / Florosilicone

Weight

8.3 pounds (3.9 kg) aluminum 

20.5 pounds (9.3 kg) stainless steel

Table IV: Positioner Specifications

Deadband

<0.1% full scale

Repeatability

<0.05% full scale

Linearity

<0.5% (rotary), <0.8%, (sliding stem) full scale

Air Consumption <0.3 SCFM (0.5 Nm

3

/hr) @ 60 psi (4 bar)

Air Supply

30-150 psig (ISA 7.0.0.1 compliant)

Air Delivery

12 SCFM @ 60 psi (0.27 Cv)

Housing 

Material

Cast, powder-painted aluminum or stainless steel

Soft Goods

Buna-N / Florosilicone

Weight

8.3 pounds (3.9 kg) aluminum 

20.5 pounds (9.3 kg) stainless steel

Table III: Physical Specifications

The Logix 3000MD Positioner Specifications

Specifications for Logix 3200MD

Summary of Contents for Logix 3000MD Series

Page 1: ...TECHNICAL BULLETIN Logix 3000MD Series Digital Positioner Experience In Motion...

Page 2: ...es at a glance using the highly visible LEDs Users can easily determine if a valve or actuator is functioning properly and quickly diagnose any problems using the smart LED blink codes This means that...

Page 3: ...ration Logix 3000MD Positioner Overview The Logix 3000MD Series Digital Positioner How It Works Tuning Unlike other positioners that have only one set gains to set the response of the positioner the L...

Page 4: ...FISCO Compliant User Interface P Polarity Insensitive UI Potted UI P AO Block 30mS P PID Block 6 PID Equations 90mS P 2 DI Block 20mS P 1 DO Block 30mS P 1 IS Block 50mS P 1 OS Block 50mS P LAS Link...

Page 5: ...bility Tuning P Integral 4 20 mA Feedback Option P Flash RAM Local Positioner Embedded Code Upgrade P Local Valve Signature Storage P Local Calibration and Setup P 24 7 Local Fault Monitoring P Local...

Page 6: ...d device and local validation that setup is correct make any HART installation easy and straightforward With the Logix 3200MD the local interface shown to the right can be used to set up the unit in s...

Page 7: ...ludes pressure sensors and full featured valve diagnostics HART Command 1 3 9 33 48 Burst Mode available to continuously transmit Position command analog loop current Final value of command after char...

Page 8: ...s instantly displayed on the local interface and through the ValveSight DTM software The health bars in the Dashboard view instantly indicate any developing issues and quickly direct the user to the i...

Page 9: ...Custom Units of Measure P P P3 P P P3 P P All Variable Editor P P P P P P P P C alibration Analog Output Calibration P P P P P Analog Input Calibration P P P P P Stroke Calibration P P P P P P P P Pre...

Page 10: ...mmunication active Communications HART Protocol ITK 5 6 Minimum Operating Current 3 6 mA without AO board 3 7 mA with AO board Maximum Voltage 30 0 VDC Table II Environmental Conditions Operating Temp...

Page 11: ...ators 33 B 173298 35 4 173298 6 7 70 10 173298 Valtek Trooper 166636 0 75 1 50 Std Automax R314 141180 HD SNA115 NK313A Vangard 37 64 175128 Air Torque AT Series AT0 AT6 Consult factory Automax SNA Se...

Page 12: ...FS DPOEVJU QPSUT 15 UISFBE PQUJPOBM 4VQQMZ 0VUQVU BOE 0VUQVU QPSUT 15 UISFBE OEJDBUPST BJO PWFS VTUPNFS OUFSGBDF PWFS 4QPPM 7BMWF PWFS BOE 7FOU SJWFS PWFS 4RVBSF PMMPXFS BSN MJNJU JT GSPN QPTJUJPO TIP...

Page 13: ...ally Safe Ex ia IIC T4 Tamb 400 C to 850 C T5 Tamb 400 C to 550 C Ex ia D 20 T950 C 400 C to 800 C ATEX II 1 G D CENELEC GOST GGTN Ex i Intrinsically Safe IIC 15 3400MD IECEx Explosionproof 16 IECEx I...

Page 14: ...80 C IP65 04 or 15 Intrinsically Safe II 1 G Ex ia IIC See Warning No 2 3 Ui 30 Volts Ii 100mA Pi 800mW Ci 30 nF Li 0 Co 36 nF T4 Tamb 40 C to 85 C T5 Tamb 40 C to 55 C IP65 04 Non Incendive II 3 G E...

Page 15: ...I II Div 2 Groups A B C D See Warning No 2 Not Required T4 Tamb 80 C Type 4X ATEX 28 Explosionproof Flameproof II 2 GD Ex d IIB H2 Ex tD A21 T95 C See Warning No 1 2 Not Required T5 T 40 C to 80 C IP...

Page 16: ...be accurate they are supplied for informative purposes only and should not be considered certified or as a guarantee of satisfactory results by reliance thereon Nothing contained herein is to be const...

Reviews: