36
11.2.4
’Check’ Mode.
’Check’ mode
is intended for indication of parameters which should be checked.
’Check’ mode
doesn’t interrupt measuring process and can be used either by auditor or by
user. In particular, in this mode counters of entries into ‘Setup’ and ‘Verification’ modes are
displayed.
11.2.5
’Setup’ Mode.
’Setup’ mode is used during meter commissioning
for hydraulic zero setting in volume
measurement channels, input of necessary parameters (pressure, etc.), and also for choosing
an appropriate mode.
It should be considered that in account modes “In account” and “Stopped” menu of
‘Verification’ mode is blocked. In addition, those items of ‘Setup’ mode which should be
unchangeable during process of measurement are also blocked.
11.2.6
’Verification’ Mode.
’Verification’ Mode
is used to evaluate measuring errors and calculating errors of ba-
sic meter performance, and also to check correctness of their indication.
’Verification’ Mode
is used for automation of water meter performance verification in
case of regular verification. Verification is conducted only by authorised personnel.
11.2.7
‘Limit prolongation’ Mode.
It is intended for password entering if time limit prolongation is needed.
11.2.8
Password entering.
Entry into service modes
‘Setup’ and ‘Verification’
is permitted only after entering
the proper passwords
to avoid non-authorized access
to parameters saved in calculator
memory. To run a proper mode in the menu password is requested.
The manufacturer set the following
standard passwords for service modes
(see table
11.1):
Table 11.1
MODE
STANDARD PASSWORD
«Setup»
25205757
On customer’s demand the manufacturer can set
INDIVIDUAL PASSWORDS
for
service modes, that is equivalent to additional
ELECTRONIC SEALING
of the calculating
unit and provides inaccessibility of unauthorized users to saved up measuring information.
The password is represented by 8-digit integer number to get access to one of service
modes.
Symbols
«-
» on the indicator mark bits for entering password digits.
Non-masked (open) value of input digit is displayed only in that digit place, in which
input of its values (editing) is provided.
While entering a password, press the button "To the right" to move the cursor on one
digit place to the right. It allows to change any digit of the password.
Pressing buttons «Up» and «Down» leads to a change in the digit value.
Pressing the button «To the left» means ending of password entering.
If during 2 minutes there was no pressing any button the meter switches from ‘Enter
password’ mode to ‘Indication of main parameters’ mode.
On figure 11.1 the way to run ‘Setup’ mode is given.
Summary of Contents for SVTU-11B
Page 1: ...Water meter SVTU 11B Operating manual SMP 407251 010 Part 1 September 2010...
Page 2: ......
Page 29: ...29 Figure 9 7 Installation of R D S of type 2 3 and 4 without thermal pocket...
Page 30: ...30 Figure 9 8 Installation of R D S of type 2 3 and 4 with thermal pocket...
Page 37: ...37 Figure 11 1...
Page 40: ...40 Figure 121 1...
Page 49: ...49 Appendix C Overall and connecting dimensions of calculator 17...
Page 51: ...51...
Page 52: ...52 Indication of main parameters mode...
Page 53: ...53 Check mode...
Page 54: ...54 Setup mode...
Page 55: ...55 Setup Set zero mode Setup PS parameters mode...
Page 56: ...56 Setup Pressures mode...
Page 61: ...61 Schematic of device cable...
Page 62: ...62 Pinout of connectors...
Page 64: ...64 Appendix L Overall and connecting dimensions for flow measurement sections FS...
Page 65: ...65 Overall and connecting dimensions for FS 32...