>> Pipe hoop Fix
For pipes can’t
be welded directly like cast iron pipe, cement pipe, copper pipe and
composite pipe, customized pipe hoop is recommended.
The hoop center should be overlapped with the transducer installation point. Please
compress the sealing gasket tightly to avoid leaking.
5)
Open hole
After finishing the installation of ball valve and base, insert the open
-
hole tool into ball
valve and lock it. Then open the ball valve, start drilling, from slow to fast. Close ball
valve after drilling.
See more details in the video of
insertion transducer installation.
6)
Install transducer and adjustment
Adjust the proper insertion depth and transmit direction to get good ultrasound signal.
>> Insertion depth adjustment
Adjust the depth scale according to pipe wall thickness, and completely push in
thetransducer rod.
Page 19