![Flottweg TRICANTER Z 8E Operating Instructions Manual Download Page 49](http://html1.mh-extra.com/html/flottweg/tricanter-z-8e/tricanter-z-8e_operating-instructions-manual_2307730049.webp)
Flottweg
Flottweg-SIMP-CONTROL®
2.2 Configuration of the control
To achieve the optimum separation result, the setting of operating mode, control
parameters and limiting values must be adapted to the product during commissioning.
Operation mode
Button
automatic operation
Button
manual operation
Parameters which are always active:
-
Limits of the differential speed (output signals “Ymin“ and “Ymax“)
-
Switch-off limiting values “Product feed off“ and “Bowl off“)
Parameters which are only active at automatic operation:
-
Nominal torque value (W)
-
Fixed value Y2
-
Controller dynamics (Xp, Tn, Tv)
Table parameters and presettings:
Parameter
Setting
Adm. range
W
Nominal torque value
According to separation task
5-90%
Y min.
min. output signal
In general 5 %
5-30%
Y max.
max. output signal
In general 90%
80-100%
Xp1
Proportional range
approx. 20%
(according to experience)
0,1-999,9%
Tn1
Reset time
approx. 80s (acc.to experience)
10-300 s
Tv1
Derivative time
1s
0,5-1,5s
Product feed off
According to separation task
(at delivery 15% over nominal
torque value W)
5-30 %
Bowl drive off
According to separation task
(at delivery 90%)
60-100 %
Y 2
Fixed value differential
speed
In general 75%
5-100%
Note:
The stipulated setting values relate to the controllers supplied by Flottweg. Controllers
of other brands might feature a different control behaviour and thus require other
settings.
U
k-
6
_
2
_
3
x8
-S
IM
P
-O
P
_
0
8
1
2
0
9
–
P
re
_
W
O
H
Summary of Contents for TRICANTER Z 8E
Page 5: ...Flottweg 1 GENERAL Uk1 allg_030107 Pre...
Page 15: ...Flottweg 2 OPERATION Uk2 allg_030107 Pre...
Page 24: ...Flottweg 3 LUBRICATION AND INSPECTION Uk3 allg_030107 Pre...
Page 37: ...Flottweg 4 OPERATING TROUBLES Uk4_1 allg_030107 Pre...
Page 44: ...Flottweg 5 TABLES AND DIAGRAMS Uk5 allg_030107 Pre...