![Flottweg TRICANTER Z 8E Operating Instructions Manual Download Page 29](http://html1.mh-extra.com/html/flottweg/tricanter-z-8e/tricanter-z-8e_operating-instructions-manual_2307730029.webp)
Flottweg
Lubrication instruction
3.2/1-3
4. Lubricant
Type:
see lubricating diagram, page 3.1
Quantity:
1,75 liter (first filling 2,7 liter)
5. Faults
Problem
Cause
Action
Pressure switch air (6)
activated
Air pressure supply
disturbed
Restore air pressure supply
"air pressure missing"
Filter contaminated
Replace filter
Pressure reducer (3)
misadjusted
Check adjustment
Pressure switch (6)
misadjusted
Check adjustment
Solenoid valve (2) closed
Check solenoid valve
Release solenoid valve
Pressure switch air (7)
activated
Air pressure too low
Check air pressure supply
"oil pressure missing"
Lack of oil
Refill oil
Manual operation at
valve (9) arrested
Release interlock
Piston pump defective
Renew piston pump
Float switch (8)
activated
Oil level below “MIN”
Refill oil