![Flotec SUB 6S Use And Maintenance Manual Download Page 8](http://html1.mh-extra.com/html/flotec/sub-6s/sub-6s_use-and-maintenance-manual_2307686008.webp)
GB
6
GB
3
Ch. 5 STARTING THE UNIT
WARNING
WARNING
Do not operate the electropump without liquids, to avoid
damaging hydraulic parts and seal.
Use the electro-pump in the performance field listed on
the information label
WARNING
Do not oparate the electropump when the interception valve
on the delivery side is completely closed.
Connect the pipe to the 1" 1/4 delivery mouth before starting the electropump.
Connections must be made so as to avoid losses.
Start the pump by inserting the plug in an appropriate outlet
.
In ordinary working conditions electropumps of the
SUB
series do not need any maintenance.
It may be occasionally necessary to clean the filter or other hydraulic parts.
If the electropump is not going to be used for long periods of time (e.g. an entire season) it should be completely emptied,
rinsed with clean water and stored in a dry place.
Cleaning the filter
- If the sucked water is not perfectly clean, it may be necessary to clean the filter with a steel brush to scrape the
dirt accumulated on the external surface.
It is also possible to clean the internal section of the filter.
Loosen the screw that fixes the filter to the body of the electropump and remove it.
Scrape the dirt with a steel brush and rinse it with clean water.
If this is not sufficient, have the hydraulic parts cleaned by an authorised centre.
Ch. 6 - MAINTENANCE AND TROUBLESHOOTING
DANGER
Electric
shock risk
Make sure the machine is disconnected from electric power
supply, before performing servicing oparationn.
The electricity supply cable must be replaced by specialised
personnel; contact your reseller.
1) No power.
2) Motor protection tripped.
3) Defective condenser.
4) Shaft blocked.
1) Check the presence of voltage and if the plug is plugged in
properly.
2) Verify the cause and reset the switch. If the thermal circuit
breaker has tripped wait for the system to cool down.
3) Replace the condenser.
4) Verificare la causa e sbloccare l’elettropompa
1) The pump is sucking air.
2) The pump rotates in the wrong
direction
3) Suction grid blocked.
4) Check valve blocked.
1) Check:
a) that the joints are sealed
b) that the level of the liquid has not gone below the
minimum priming level
2) Reset the direction of rotation.
3) Clean the filter
4) Clean or replace valve.
1) Check the voltage on the power supply cable leads.
2) Take the electro-pump apart and clean it
3) Change the type of electropump.
If the problem cannot be eliminated after carrying out the above-described operations contact the closest service centre.
DANGER
Electric
shock risk
PROBLEM POSSIBLE CAUSE REMEDY
THE ELECTROPUMP DOES
NOT PUMP WATER, THE MO-
TOR DOES NOT RUN
THE MOTOR RUNS BUT THE
ELECTROPUMP DOES NOT
PUMP LIQUID
THE ELECTROPUMP STOPS
AFTER RUNNING FOR A
PERIOD OF TIME BECAUSE
ONE OF THE THERMAL
MOTOR CIRCUIT BREAKER
TRIPS
1) The power supply does not conform
with the data on the nameplate.
2) A solid object is blocking the impellers.
3) The liquid is too thick.
Summary of Contents for SUB 6S
Page 54: ...RUS 52 1 RUS 1 SUB 8 FLOTEC SUB 1 2 3 4 5 6 RUS 1 RUS 2 RUS 2 RUS 2 RUS 3 RUS 3...
Page 59: ......
Page 60: ......