Flotec FPSC2150A Owner'S Manual Download Page 4

For parts or assistance, call Flotec Customer Service at 

1-800-365-6832

Troubleshooting

4

2

Slip the float and then the rod stop
onto the rod past the second nib.

1

Mount the bracket onto the switch
housing.

4 Attach the switch to the pump as shown.  

Vertical Switch Assembly

Rod

Rod Stop

Float

Bracket

Bracket
Mounting
Screws

Switch

Housing

Pin

3 Insert the rod assembly up into the

switch housing and lock into place
with the pin.  

NOTICE:

 Be sure the pin holds the

rod into  the switch housing or the
pump will not shut off.

SYMPTOM

PROBABLE CAUSE(S)

CORRECTIVE ACTION

Pump won’t start or run.

Pump is not plugged in.

Check and see if pump is plugged in to a proper outlet.

Blown fuse or tripped breaker.

Replace with fuse of proper size. If tripped,reset breaker.

Low line voltage.

If voltage under recommended minimum, check size of wiring
from main switch on property. If OK, contact power company 
or hydro authority.

Defective motor.

Replace pump.

Defective float switch.

Replace float switch.

Impeller.

If impeller won’t turn, remove lower pump body and locate 
source of binding.

Float obstructed.

Remove obstruction.

Pump starts and stops

Backflow of water from piping.

Install or replace check-valve.

too often.

Faulty float switch.

Replace float switch.

Pump won’t shut off.

Defective float switch.

Replace float switch.

Restricted discharge 

Remove pump and clean pump and piping.

(obstacle or ice in piping).
Float obstructed.

Remove obstruction.

Restricted intake screen.

Remove the pump and clean the intake screen and the
impeller.

Pump operates but

Low line voltage.

If voltage under recommended minimum, check size of wiring 

delivers little or no water.

from main switch on property. If OK, contact power company 
or hydro authority.

Something caught in impeller.

Remove the pump and clean out the impeller.

Worn or defective parts or

Clean impeller if plugged; otherwise replace pump.

plugged impeller.
Check valve installed without

Drill a 1/16" - 1/8" (1.6mm - 3.2mm) dia. hole between pump 

vent hole.

discharge & check valve (1-2” above where the discharge
pipe screws into the pump discharge and below the 
waterline).

Restricted intake screen.

Remove the pump and clean out the intake screen.

Check valve is installed either

Be sure check valve is installed correctly.

backward or upside down.

TROUBLESHOOTING CHART

Summary of Contents for FPSC2150A

Page 1: ...ages 2 6 Installation Fonctionnement Pi ces Pour plus de renseignements concernant l utilisation l installation ou l entretien Composer le 1 800 365 6832 Fran ais Pages 7 11 Instalaci n Operaci n Piez...

Page 2: ...rge line will whip possibly causing personal injury and or property damage 7 Check hoses for weak or worn condition before each use making certain that all connections are secure 8 Periodically inspec...

Page 3: ...5 V 60 Hz operation and requires a minimum 15 amp individual branch circuit Both pump and switch are supplied with 3 wire cord sets with grounding type plugs Switch plug is inserted directly into outl...

Page 4: ...and locate source of binding Float obstructed Remove obstruction Pump starts and stops Backflow of water from piping Install or replace check valve too often Faulty float switch Replace float switch...

Page 5: ...PSC3150A 1 Power Cord Assembly 1 PS117 54 TSU PS117 53 TSU 2 Screw 1 U30 955PS U30 955PS 3 Vertical Float Switch Assembly 1 FPS17 66 FPS17 66 4 Screw 8 32x7 8 Hex Head 4 U30 951PS U30 951PS 5 Motor 1...

Page 6: ...0AC FP0FDC 1 3 HP Submersible Sump Pumps Pool Cover Pump Model FP0S1790PCA Utility Pump Model FP0S4100X 2 Years Condensate Pump Model FPCP 20ULST INTELLIPUMP Model FP0S1775A Back up Sump Pump System M...

Page 7: ...ctionner la pompe Une canalisation de refoulement non immobilis e risque de se d placer comme un fouet et de causer des blessures corporelles et ou des dommages mat riels 7 Avant chaque utilisation s...

Page 8: ...surer de percer le trou sous le niveau de l eau et sous le clapet de non retour pour emp cher la formation de bouchons d air 7 Courant lectrique La pompe est con ue pour fonctionner sur le courant lec...

Page 9: ...se du blocage Obstruction du flotteur D gager le mouvement du flotteur La pompe d marre et Reflux du liquide dans Installer un clapet de retenue s arr te trop souvent la pompe Interrupteur du flotteur...

Page 10: ...cord n lectrique 1 PS117 54 TSU PS117 53 TSU 2 Vis 1 U30 955PS U30 955PS 3 Interrupteur flotteur vertical 1 FPS17 66 FPS17 66 4 Vis t te hexagonale n 8 32 x 7 8 de pouce 4 U30 951PS U30 951PS 5 Moteur...

Page 11: ...pe usage g n ral mod le FP0S4100X INTELLIPUMP mod le FP0S1775A 2 ans Pompe de r cup ration des eaux condens es mod le FPCP 20ULST Syst me de pompage de secours de puisard de soutien mod le FP2800DCC P...

Page 12: ...n marcha la bomba Una tuber a de descarga que no est bien segura puede moverse y causar lesiones personales y o da os materiales 7 Antes de cada uso verifique si las mangueras est n d biles o gastadas...

Page 13: ...omba est dise ada para funcionar con corriente de 115 V 60 Hz y requiere un ramal individual m nimo de 15 amps Tanto la bomba como el interruptor vienen con juegos de cordones de 3 conductores con enc...

Page 14: ...onde el rodete se traba El movimiento del flotante Retire las obstrucciones est obstruido La bomba se pone en Hay retroceso de agua de Instale una v lvula de retenci n marcha y se detiene con la tuber...

Page 15: ...de corriente 1 PS117 54 TSU PS117 53 TSU 2 Tornillo 1 U30 955PS U30 955PS 3 Unidad del interruptor de flotador vertical 1 FPS17 66 FPS17 66 4 Tornillo cabeza hexagonal 8 32x7 8 4 U30 951PS U30 951PS 5...

Page 16: ...e agua en l nea 90 d as Bomba para todo uso modelos FP0F360AC FP0FDC Bombas de sumidero sumergibles de 1 3 HP INTELLIPUMP modelo FP0S1775A Bomba para cubiertas de piscina modelo F0S1790PCA 2 a os Bomb...

Reviews: