Flotec FP4000 Series Owner'S Manual Download Page 11

Repair Parts 

Ref .

Part Description

FP4112 and FP4112C

FP4122 and FP4122C

1

Motor

J218-582A-115-PKG

J218-590PKG

2

Seal Plate Assembly

N3-1043P

3

Seal and Gasket Kit**

FPP1550

4

Pump Body Assembly§

N176-38

N176-38F

5

Overhaul Kit§§

FPP1560

FPP1561

6

Pressure Switch

TC2151

**  Includes: Water slinger, seal plate O-Ring or gasket, shaft seal, and diffuser O-Ring or gasket.

§ Includes: Pump body, nozzle, and venturi.

§§  Includes: Seal and Gasket Kit (Ref. 3), impeller, and diffuser.

2490 0696

1

2

5  (Includes
Key No. 3)

6

4

AVC

Port

Summary of Contents for FP4000 Series

Page 1: ...OWNER S MANUAL Shallow Well Jet Pumps Installation Operation Parts 2489 0696 558 0397 FP4000 FP4100 FP4800...

Page 2: ...terminals together Do not touch metal screwdriver blade or capacitor terminals If in doubt consult a qualified electrician General Safety Risk of burns Do not touch an operating motor Motors are desi...

Page 3: ...n port on the pump include a check valve if your pump is not equipped with one see Figure 1 Support the pipe so that there are no dips or sags in the pipe so it doesn t strain the pump body and so tha...

Page 4: ...lbows in the suction pipe The suction pipe should be at least as large as the suction port on the pump 2 Assemble a foot valve and suction pipe see Figure 3 Make sure that the foot valve works freely...

Page 5: ...pipe size must be at least as large as the discharge port 3 Install a tee in the suction pipe near the pump Install a reducer bushing down to 1 8 NPT in the tee Run tubing from the tee to the port on...

Page 6: ...sure switch as shown in Figure 8 4 Attach the ground wire to the grounding connections as shown in Figure 8 5 If there are other wires they should be capped 6 Reinstall the motor end and pressure swit...

Page 7: ...ust be a solid copper wire at least as large as the power supply wires 2 There must be a solid metal connection between the pressure switch and the motor for motor grounding protection If the pressure...

Page 8: ...at this several times in order to get all the trapped air out of the piping A pump lifting water 25 may take as long as 15 minutes to prime 4 After the pump begins building pressure in the system shut...

Page 9: ...valve and or strainer are buried in sand or mud Raise foot valve and or strainer above bottom of water source Clean foot valve and strainer Water level is too low for shallow well setup to deliver wa...

Page 10: ...ft Seal 1 U9 6 5 Impeller 1 J105 40PNB J105 42PNB 5A Floating Wear Ring 1 N23 12SS 6 Priming Baffle 1 U97 153P 7 Nozzle Venturi Diffuser Assembly 1 N101 30PA N101 30P 8 Nozzle O Ring 1 U9 449 9 Pump B...

Page 11: ...d Gasket Kit FPP1550 4 Pump Body Assembly N176 38 N176 38F 5 Overhaul Kit FPP1560 FPP1561 6 Pressure Switch TC2151 Includes Water slinger seal plate O Ring or gasket shaft seal and diffuser O Ring or...

Page 12: ...g 1 111P0500 6 Impeller 1 101P1720 101P1730 7 Venturi 1 101P2900 8 O Ring 1 111P1100 9 90 Hose Barb 1 171P4750T 10 Pump Body 1 723S0850 11 12 Plug Stainless Steel Washer 1 111P0990 13 Screw Socket Hea...

Reviews: