Electrical 3

For parts or assistance, call Flotec Customer Service at 

800-365-6832

Piping – Effluent Applications 

(3/4” or Less Solids)

Piping must be 1-1/2” minimum to carry volume of 

pump discharge. Check local codes to determine if a 

check valve is required in your system. In cold climates, 

check valves are not used to prevent effluent from 

freezing in piping.

Piping – Sewage Applications  

(2” or Less Solids)

In any case, piping must not be smaller than pump discharge.
When installed in a sewage system, pipe must be capable 

of handling semi-solids of at least 2” (5.1 cm) diameter.
The rate of flow in the discharge pipe must keep any 

solids present in suspension in the fluid. To meet 

minimum flow requirements (2 feet (.6 m) per second in 

discharge line), size pipe as follows:

NOTICE Use PTFE pipe thread sealant tape on pipe 

connections. Do not use ordinary pipe joint compound 

on plastic pipe or pump. Pipe joint compound can attack 

plastics and damage pump.

3.  To reduce motor noise and vibrations, a short length 

of rubber hose can be connected into discharge line 

near pump using suitable clamps. 

4.  If the pump discharge line is exposed to outside 

subfreezing atmosphere, then the portion of line 

exposed must be installed so any water remaining 

in pipe will drain to outfall by gravity. Failure to do 

this can cause water trapped in discharge to freeze 

which could result in damage to pump.

5.  Install a 2” check valve in the horizontal portion of 

the discharge pipe. Make certain, the flow indicating 

arrow, points away from the pump. This check valve 

will keep the water from either running back into the 

basin or into the area being pumped out when the 

pump is not running. Check valve should be a free 

flow valve that will easily pass solids.

NOTICE For best performance of check valve when 

handling solids, do not install it with discharge angled 

more than 45° above the horizontal. Do not install check 

valve in a vertical position as solids may settle in valve 

and prevent opening on startup.
6.  Drill a 3/16” (4.7mm) hole in discharge pipe 

about 1”-2” (2.5 - 5.1cm) above pump discharge 

connection (but below check valve) to prevent 

airlocking the pump.

7.  Insert the float switch piggy-back plug into a 

properly grounded outlet and the pump plug into the 

piggy-back plug.

8.  Check the installation by observing the pump 

operation through one complete cycle. Make sure that 

no parts of the assembly interfere with the float switch.

 Risk of flooding. Can cause personal injury 

and/or property damage. Failure to make this operational 

check may lead to improper operation, premature failure, 

and flooding.

ELECTRICAL

 Risk of electric shock. Can shock, burn or 

kill. When installing, operating, or servicing this pump, 

follow safety instructions listed below.
1.  DO NOT splice the electrical power cord.
2.  DO NOT allow electrical cord plug to be submerged.
3.  DO NOT use extension cords. They are a fire hazard 

and can reduce voltage sufficiently to prevent 

pumping and/or damage motor.

4.  DO NOT handle or service pump while it is connected 

to power supply.

5.  DO NOT remove grounding prong from plug or 

modify plug.To protect against electrical shock, the 

power cord is a three-wire conductor and includes a  

3-prong grounded plug. Plug pump into a 3-wire, 

grounded, grounding-type receptacle. Connect pump 

according to electrical codes that apply.

Not

to

Scale

2” Check Valve

Mount Horizontally!

Direction 

of Flow

2” Discharge 

Pipe

18”

30”

Plug Switch into

115V, 3-Prong, 

Grounded Outlet

Plug Pump into

Switch Plug

Sewage

Basin

Drill 3/16” Vent 

Hole Here

Install the Pump on a

Hard, Level Surface

Float Switch must

Swing Through

Its Entire Arc

6164 0310

Figure 1 - Typical Installation

A Pipe Size of

Will Handle a Flow Rate of:

1-1/2” (3.8 cm)

12 GPM (45 LPM)

2” (5.1 cm)

21 GPM (79 LPM)

2-1/2” (6.3 cm)

30 GPM (113 LPM)

3” (7.6 cm)

48 GPM (181 LPM

Summary of Contents for E75STVT-01

Page 1: ...l 800 365 6832 English Pages 2 6 Installation Fonctionnement Pi ces Pour plus de renseignements concernant l utilisation l installation ou l entretien Composer le 800 365 6832 Fran ais Pages 7 11 Inst...

Page 2: ...anyone handling it and will void warranty 7 Pump normally runs hot To avoid burns when servicing pump allow it to cool for 20 minutes after shut down before handling it 8 Motor has been filled at the...

Page 3: ...solids do not install it with discharge angled more than 45 above the horizontal Do not install check valve in a vertical position as solids may settle in valve and prevent opening on startup 6 Drill...

Page 4: ...pump by power cord See Cord Lift Warning below Submerge pump in a disinfectant solution chlorox or chlorine for at least one hour before servicing pump The pump motor contains a special lubricating o...

Page 5: ...r check valve or discharge pipe THermal overload may have tripped Test start pump if it starts and then stops immediately disconnect power source for 30 minutes to allow motor to cool then reconnect t...

Page 6: ...vice Sewage pumps that have seen service and been removed carry a contamination hazard with them If your sewage pump has failed Wear rubber gloves when handling the pump For warranty purposes return t...

Page 7: ...e sur chauf fer et de cau ser ain si des br lu res et an nu le la ga ran tie 7 La pom pe chauf fe lors qu elle fonc tion ne Pour vi ter les br lu res lors des in ter ven tions sur la pom pe la lais se...

Page 8: ...pas l installer non plus en position verticale tant donn que les mati res solides se d poseront sur son battant et l emp cheront de s ouvrir au d marrage de la pompe 6 Percer un trou de 4 7 mm 3 16 po...

Page 9: ...rt Avant de re ti rer la pom pe du bas sin pour une in ter ven tion d con nec ter l ali men ta tion de la pom pe et du bo tier de com man de Risque de secousses lectriques Pouvant causer des br lures...

Page 10: ...ion Le disjoncteur de surcharge thermique a peut tre fonctionn V rifier le d marrage de la pompe si la pompe d marre et s arr te aussit t la d connecter de la source d alimentation Rechercher la cause...

Page 11: ...entent un risque de contamination En cas de d faillance de la pompe d eaux d gout Porter des gants en caoutchouc pour manipuler la pompe des fins de garantie retourner l tiquette figurant sur le cordo...

Page 12: ...en caliente Para evitar quemaduras al prestar servicios a la bomba d jela enfriar 20 minutos despu s de desconectarla y antes de manipularla 8 El motor viene lleno de f brica con un aceite especial E...

Page 13: ...ci n en posici n vertical ya que las part culas s lidas podr n asentarse en la v lvula y evitar que se abra cuando la bomba se encienda 6 Perfore un orificio de 3 16 4 7 mm en la tuber a de descarga e...

Page 14: ...tom ticamente y permite el arranque del motor Si el protector de sobrecarga funciona con excesiva frecuencia investigue los motivos La sobrecarga podr a deberse a un rodete trabado al uso de voltaje e...

Page 15: ...ionado Haga arrancar la bomba si arranca y se detiene de inmediato desconecte la bomba de la corriente el ctrica por 30 minutos para permitir que el motor se enfr e luego vuelva a conectarla a la corr...

Page 16: ...epartamento de Atenci n al Cliente de FLOTEC Las bombas cloacales que hayan estado en servicio y se hayan removido pueden representar un peligro de contaminaci n Si su bomba cloacal ha fallado Use gua...

Reviews: