12.0 Technical Investigation – Tests 

12.1 

Tests were carried out and the results assessed against BS EN 12380: 2002 to deternine:

• 

impact resistance (drop test)

• 

airtightness after endurance at negative temperature

• 

airtightness before and after endurance at positive temperature

• 

opening pressure

• 

airflow capacity

13.0 Technical Investigation  

13.1

 The manufacturing process applied to these products are controlled with FloPlast BS EN ISO 9001: 2015 Quality 

Management System (Certificate No. FM501414). These processes are regularly audited by representatives of BSI to 

ensure continued compliance with our detailed processes.

13.2

 FloPlast’s valves are subject to type testing and audit test as deterrmine with the Kitemark scheme to which they 

are certified, (Certificate KM512474). Testing is undertaken on behalf of BSI at the Building Research Establishment also 

known as BRE. 

14.0 Bibliography   

BS 4514 : 2001

 Unplasticized PVC soil and ventilating pipes of 82.4 mm minimum mean, outside diameter and fittings 

and accessories of 82.4 mm and of other sizes — specification

BS 5255: 1989

 Specification for thermoplastics waste pipe and fittings

BS EN 1329-1: 2014

 Plastics piping systems for soil and waste discharge (low and high temperature) within the building 

structure — Unplasticized poly(vinyl chloride) (PVC-U)

BS EN 1455-1: 2000

 Plastics piping systems for soil and waste (low and high temperature) within the building structure. 

Acrylonitrile-butadiene-styrene (ABS). Specifications for pipes, fittings and the system

BS EN 1565-1; 2000

 Plastics piping systems for soil and waste discharge (low and high temperature) within the building 

structure — Styrene copolymer blends (SAN + PVC) — Specifications for pipes, fittings and the system

BS EN 1566-1 : 2000

 Plastics piping systems for soil and waste discharge (low and high temperature) within the building 

structure — Chlorinated poly(vinyl chloride) (PVC-C) — Specification for pipes, fittings and the system

BS EN 12056-1 : 2000

 Gravity drainage systems inside buildings — General and performance requirements

BS EN 12056-2 : 2000

 Gravity drainage systems inside buildings — Sanitary pipework, layout and calculation

BS EN 12380: 2002

 Air admittance valves for drainage systems — Requirements, test methods and evaluation of 

 

conformity 

BS EN ISO 9001 : 2015

 Quality management systems — Requirements

Summary of Contents for AF110

Page 1: ...itish Standards Kitemark KM512474 and CE mark as having met the performance requirements of BS EN 12380 2002 and have been designated with an A1 rating FloPlast s Air Admittance Valves provide a means...

Page 2: ...the installation part of this document Building standards applicable to construction Wastewater drainage The valves can meet the relevent requirements of this Standard with reference to clauses 3 7 7...

Page 3: ...also be installed directly into 100mm or 110mm European designated pipe with the use of an EPDM finned seal this product is designated AFE110 FloPlast s AF110 Air Admittance Valve as seen on the fron...

Page 4: ...socket 82 82 0 82 3 BS EN1329 1 BS 4514 PVC AF110 AX110 Push Fit 110 110 0 110 3 BS EN 1329 1 BS EN 1455 1 BS EN 1565 1 BS EN 1566 1 BS 4514 BS5255 Multi AV110 Solvent Weld 110 110 0 110 3 BS EN1329 1...

Page 5: ...on instructions are supplied in cardboard boxes and polyethylene bags to limit the risk of contamination or damage All valves must be stored upright in their boxes until required for use 3 2 The legen...

Page 6: ...wellings a ventilated by FloPlast AVE100 AV110 AF110 or AX110 FloPlast AVE100 AV110 AF110 or AX110 FloPlast AF32 or AFE32 Minimum 200mm Greater than 4 metres b unventilated Up to 4 metres NOTES The ma...

Page 7: ...le 3 and Figure 5 Table 3 Air admittance valve disposition Number of Dwellings Up to three stories in height Multi storey domestic dwelling and non domestic buildings 1 4 Additional drain and venting...

Page 8: ...suitable form of sound insulation 6 8 In addition other than those shown in Figure 5 stacks should not be fitted with the valves when the connecting drain s are subject to periodic surcharging or are...

Page 9: ...ied out in accordance with these instructions 11 2 FloPlast AF110 AX110 valves are supplied with a synthetic rubber connector enabling a push fit into 100mm and 110mm as indicated in Table 1 Additiona...

Page 10: ...ecification BS 5255 1989 Specification for thermoplastics waste pipe and fittings BS EN 1329 1 2014 Plastics piping systems for soil and waste discharge low and high temperature within the building st...

Page 11: ...c Are reviewed by the BSI as and when it considers appropriate 15 4 In issuing this document FloPlast is not responsible for a the right of the document holder to market supply install or maintain th...

Reviews: