FloPlast Air Admittance Valves

(Issue 2 02/2018) 

This document relates to FloPlast’s AF32, AFE32, AF110, AVE100, AV110 and AX110 valves, for use in 

 

above-ground  drainage systems and in conjunction with the Building Regulations, (PART H1).
FloPlast’s Air Admittance Valves carry the British Standards Kitemark (KM512474) and CE mark, as having met 

the performance requirements of BS EN 12380: 2002 and have been designated with an A1 rating.
FloPlast’s Air Admittance Valves provide a means of ventilation to the drainage system to prevent loss of 

water seals in traps and consequent release of foul air into the building.
The drainage system and the installation and use of FloPlast’s Air Admittance Valves must be in accordance 

with the Design Data and Installation sections of this document.

AF32

AVE100/AV110

AF110

AX110

ROO

FLI

NE

, W

IN

DO

W & CLADD

IN

G S

YS

TEM

S

RA

IN

WA

TER SYSTE

M

S

SO

IL 

WASTE SYSTE

M

S

UN

DE

RG

RO

UN

D DRAINAG

E S

YS

TEM

S

M

DP

E SYSTEMS

HO

T &

 COL

D SYST

EM

S

Summary of Contents for AF110

Page 1: ...itish Standards Kitemark KM512474 and CE mark as having met the performance requirements of BS EN 12380 2002 and have been designated with an A1 rating FloPlast s Air Admittance Valves provide a means...

Page 2: ...the installation part of this document Building standards applicable to construction Wastewater drainage The valves can meet the relevent requirements of this Standard with reference to clauses 3 7 7...

Page 3: ...also be installed directly into 100mm or 110mm European designated pipe with the use of an EPDM finned seal this product is designated AFE110 FloPlast s AF110 Air Admittance Valve as seen on the fron...

Page 4: ...socket 82 82 0 82 3 BS EN1329 1 BS 4514 PVC AF110 AX110 Push Fit 110 110 0 110 3 BS EN 1329 1 BS EN 1455 1 BS EN 1565 1 BS EN 1566 1 BS 4514 BS5255 Multi AV110 Solvent Weld 110 110 0 110 3 BS EN1329 1...

Page 5: ...on instructions are supplied in cardboard boxes and polyethylene bags to limit the risk of contamination or damage All valves must be stored upright in their boxes until required for use 3 2 The legen...

Page 6: ...wellings a ventilated by FloPlast AVE100 AV110 AF110 or AX110 FloPlast AVE100 AV110 AF110 or AX110 FloPlast AF32 or AFE32 Minimum 200mm Greater than 4 metres b unventilated Up to 4 metres NOTES The ma...

Page 7: ...le 3 and Figure 5 Table 3 Air admittance valve disposition Number of Dwellings Up to three stories in height Multi storey domestic dwelling and non domestic buildings 1 4 Additional drain and venting...

Page 8: ...suitable form of sound insulation 6 8 In addition other than those shown in Figure 5 stacks should not be fitted with the valves when the connecting drain s are subject to periodic surcharging or are...

Page 9: ...ied out in accordance with these instructions 11 2 FloPlast AF110 AX110 valves are supplied with a synthetic rubber connector enabling a push fit into 100mm and 110mm as indicated in Table 1 Additiona...

Page 10: ...ecification BS 5255 1989 Specification for thermoplastics waste pipe and fittings BS EN 1329 1 2014 Plastics piping systems for soil and waste discharge low and high temperature within the building st...

Page 11: ...c Are reviewed by the BSI as and when it considers appropriate 15 4 In issuing this document FloPlast is not responsible for a the right of the document holder to market supply install or maintain th...

Reviews: