1.0 Introduction 

The communication board enables one of the unique features of the Uniflo 1200: Adaptation to future 
demands for communication protocols, bus systems etc. 
Initially, the board includes the following functions: 
Interface for PSTN modem, incl. dial back in case of alarm. 
Interface for GSM modem, incl. dial back or text SMS in case of alarm. 
Internal bus for parallel connection of more Uniflo 1200 to the same PSTN or GSM modem. 
 
The Communication controller option board can be supplied in three ways: 
 

0618600-000  Uniflo 1200 card, 230V 

 

0618605-000  Uniflo 1200 card, Ex powersup. 

 

Lithium battery. Reference to installation manual for Uniflo 1100 & 1200 for choice of battery. 

 
Reference to “Uniflo 1200 Installation Manual” for general information. 
Reference to “Uniflo 1100 Installation Manual” for general information. 
 
Definitions 
Technicians are qualified persons educated or trained to mount, operate, and also troubleshoot technically 
correct and in accordance with safety regulations. 
 
Limitations 
This manual only applies to the following Product numbers: 061864X-YYY Uniflo 1200 card, comm.contr  
and only for mounting in a Uniflo 1100 & Uniflo 1200. 
 
If the Uniflo 1100 or 1200 has build in modem like 0618650-YYY the Uniflo need 0618600-000 Uniflo 1200 
card, 230V 
 

When mounted in Hazardous areas: 

Powersupply Uniflo 1200: Use Ex power supply 0618605-000 Uniflo 1200 or Lithium battery. 
Powersupply Uniflo 1100: Use only Lithium battery. 
Reference to installation manual for Uniflo 1100 & 1200 for choice of battery or “EX-powersupply installation 
manual”.

  

 
Limitations to its use. 
First of all the Communication board has to be placed inside the Uniflo, in such a way, that there is at least 
one option board distance to other option boards. 
The jumper on 

XJ1 has to be removed

The T, R and C ports are the only ports that can be used in a hazardous environment. 
 

2.0 Mounting 

Only technicians who are familiar with the technical terms, warnings, and instructions in the manual and who 
are able to follow these should connect the module. 

Should there be any doubt as to the correct handling of the module, please contact your local distributor or, 
alternatively, 

Flonidan DC A/S  -  Islandsvej 29  -  DK-8700 Horsens 
Tel. +45 75618888  -  Fax +45 75626088  -  E-mail: 

[email protected]

  

Mounting and connection of the module should comply with national legislation for mounting of electric 
materials, i.a. wire cross-section, protective fuse, and location. Descriptions of input / output and supply 
connections will follow in this paper. 

 
When mounting the option board please also observe the guidelines in the paper "ESD correct handling". 
 

1.  Turn off the Uniflo power supply (both battery and external supply).  
2.  Mount the Communication output board with the supplied plastic circuit board support post. 
3.  Press the option board plug into the socket on the main board (typically position OPS7). 

Summary of Contents for Uniflo 1200 GVEC

Page 1: ...lo 1200 GVEC Accessories Communication board Product number 061864X YYY Manual M 06180XX 24 Rev 23 02 2010 Please look at our homepage www flonidan dk there you will find the newest version of the document ...

Page 2: ... 3 1 GSM modem 6 3 2 PSTN modem 7 3 3 GPRS 7 4 0 More than one Uniflo connected to the same modem bus connection 9 4 1 Set up 11 4 2 Cables 11 5 0 Ex description 12 5 1 General 12 5 2 Ex data 12 5 3 Connection to external modem in nonhazardous environment 12 5 4 Bus connection in hazardous environment 13 5 5 Installation inspection and maintenance in hazardous environment 13 6 0 Technical data 13 ...

Page 3: ...o need 0618600 000 Uniflo 1200 card 230V When mounted in Hazardous areas Powersupply Uniflo 1200 Use Ex power supply 0618605 000 Uniflo 1200 or Lithium battery Powersupply Uniflo 1100 Use only Lithium battery Reference to installation manual for Uniflo 1100 1200 for choice of battery or EX powersupply installation manual Limitations to its use First of all the Communication board has to be placed ...

Page 4: ...ded cable then terminate the shield under the strain relief 6 If there is a build in GSM PSTN modem then insert the connector into KL2 7 Turn on the power supply first external supply and then battery The unit automatically starts initialising setting up the board address and adding the new parameters into Uniflo Config 8 Set up the parameters in Uniflo Config 3 0 General settings Output standard ...

Page 5: ...ia GPRS network is wanted The type of modem must be selected also if the communication board is connected to the modem via bus Mode Options MASTER Default selection SLAVE Selected when the communication board is not connected directly to a PSTN GSM modem but connected to another communication board by bus Examples of different set up s Communication board connected directly to GSM modem Settings O...

Page 6: ...ary phone no is started When connection is established the content of the ID string is transmitted to the receiving application Hereafter the communication board will change to Modbus RTU mode and communication can begin If the call doesn t succeed the communication controller will retry 10 times on the Primary phone no and then switch to Secondary phone no for another 10 retries The following set...

Page 7: ...uter receiving alarm calls Secondary phone no Phone no to use if primary phone no is not responding after having tried 10 times ID string Enter Uniflo ID no to send to host computer Send ID Must be marked 3 3 GPRS The GPRS option can be used to transfer log data as soon as they have been logged It requires a GPRS modem and an Internet connection with Flonidan GPRS gateway to receive data If more t...

Page 8: ... in these under APN username and APN password 6 Type in the IP address of the server to send log data to under Server IP address 7 If a different loginterval than what the Uniflo 1200 can deliver is wanted this can be entered under Send data every If this option is used be aware that the loginterval of the Unilfo 1200 must be less than the derisred interval and the loginterval of the Uniflo 1200 m...

Page 9: ...ore than one Uniflo connected to the same modem bus connection System overview Two or more Uniflo s can be connected to the same modem to save money on both the modem and the monthly fee s A connection between two Uniflo s can be seen in the following diagram Uniflo 1200 MASTER Uniflo 1200 SLAVE Communication board Standard modem GSM PSTN modem To next Uniflo Daisy Chain connection Communication b...

Page 10: ...ions between the two Communication boards shows that the T C and R has to be connected and only the Communication board in the MASTER is connected to the GSM PSTN modem T RC Communication board MASTER Uniflo 1200 no 1 1 2 3 4 5 6 7 KL 1 KL 2 T RC Communication board SLAVE Uniflo 1200 no 2 1 2 3 4 5 6 7 KL 1 KL 2 GSM PSTN modem 1 2 3 4 5 6 TLF1 GND TLF2 Connected to the GSM PSTN modem via the Seria...

Page 11: ...E address 21 30 and so on Modbus SLAVE address is set under the Miscellaneous tab Notice Modbus SLAVE address may only be changed when using optical head or Uniwire not by modem It s recommended that the MASTER is first connected set up and tested Hereafter connect set up and test one SLAVE unit at the time 4 2 Cables Communication board to GSM PSTN cable The communication board and the GSM PSTN m...

Page 12: ...nside the Uniflo in such a way that there is at least one option board distance to other option boards The Output standard has to be selected as Optical on the configuration page for the Communication board The jumper on XJ1 has to be removed The T R and C ports are the only ports that can be used in a hazardous environment 5 2 Ex data The Communication board is classified to ia IIC T3 together wi...

Page 13: ... Electrical installations in hazardous area other than mines EN 60079 17 Electrical apparatus for explosive gas atmospheres Part 17 Inspection and maintenance of electrical installations in hazardous area other than mines It s also recommended to follow the guidelines in DS Håndbog 144 6 0 Technical data 6 1 Dimensions Drawing of Communication board F L O N I D A N A N A L O G O U T 0 6 1 8 0 20 2...

Page 14: ...ption to ATEX certificate number Option ATEX 135598X Option Option board to the following certificate ATEX 135598 Certificate number X Special conditions for safe use Read this manual for safe use New ATEX certificate number ATEX139093X ATEX CE marking CE 0539 Ex II1G ATEX CE marking according to directive 94 9 EC CE Conformance with directive 94 9 EC and other relevant standards 0539 Identificati...

Page 15: ... TF Document created 27 01 2004 TF Atex data marking changed Ex parameters updated 23 08 2004 KEN GPRS added and alarm SMS functionality changed 09 09 2005 LBF SMS setup screen added in 3 1 11 11 2005 JK ATEX relevant information is updated because of new certificate no 139093 23 02 2009 TF GPRS not able to be connected in parallel removed Flonidan DC A S Islandsvej 29 DK 8700 Horsens Tel 45 75618...

Reviews: