2001 Peristaltic Pump O&M Manual
4.0 – 2001H Drive Controller
Operation and Wiring
For complete details about the motor drive controller please refer to the included Motor Drive
Operating Instructions booklet. Shown on the following pages are details specific to operation with the
2001H Peristaltic Pump.
Programming
The programming differs from the factory defaults shown in the SM Vector Operating Instruction booklet only in
relation to the following parameters:
* Controller has been programmed for 2001 Series Settings as shown below.
PARAMETER NAME: USER SETTINGS RECORD
Parameter
Number
Parameter
Name
Factory
Default
2001 Series
Series
Settings*
0
LINE VOLTS
AUTO
-
1
SPEED #1
20 Hz
25% HZ
2
SPEED #2
20 Hz
25% HZ
3
SPEED #3
20 Hz
25% HZ
4
SPEED #4
20 Hz
25% HZ
5
SKIP #1
.00 Hz
-
6
SKIP #2
.00 Hz
-
7
BAND WID
1.00 Hz
5 Hz
8
ACCEL
30.0 SEC
5 SEC
9
DECEL
30.0 SEC
5 SEC
10
MIN FRQ
.50 Hz
0 Hz
11
MAX FRQ
60.00
75 Hz
12
DC BRAKE
.0 VDC
-
13
DC TIME
.0 SEC
-
14
DYN BRAKE
OFF
-
16
CURRENT
180 %
-
17
MOTOR OL
100 %
-
18
BASE
60.00 Hz
-
19
FX BOOST
(Note 1)
5.3 %
22
TORQUE
CONSTANT
-
23
CARRIER
2.5 kHz
12 KHz
25
START
NORMAL
POWER UP
26
STOP
COAST
-
28
AUTO/MAN
A/M LOC
A/M SPD
30
CONTROL
LOCAL
REMOTE
31
UNITS
Sp HERTZ
% Hz
32
HZ MULT
1.00
-
33
UNITS DP
XXXXX
XXX.X
34
LOAD MLT
100 %
-
35
CONTRAST
HIGH
-
36
SLEEP TH
.00 Hz
2.0 Hz
37
SLEEP DL
30.0 SEC
5.0 SEC
38
SLEEP BW
0%
39
TB5 MIN
.00 Hz
0%Hz
Flomotion Systems, Inc. 2001H SERIES
Pg. 19
Note that the % symbol
only appears if it is
selected in step 31.