To start operation, regulate gas pressure to desired
setting. For most installations, 65 PSI (4.4 bar) will be
adequate. Open dispensing valve to purge air from sys-
tem. Pump will now operate automatically by starting
and stropping on demand, as beverages are served
while maintaining constant pressure at the dispensing
valve. Product flow and pressure can be adjusted by
increasing or decreasing gas pressure to accommodate
varying product viscosities, length of lines or other
installation conditions.
Caution: Do not exceed 80 PSI
(5.5 bar) gas pressure or manufacturer’s maximum
recommended pressure.
The Flojet Model N5000 has
an automatic vacuum shutoff valve which stops the
pump by shutting off the gas supply to the pump when
the bag is empty and high vacuum builds up in the inlet
syrup line. The control will automatically restart the
pump when a new bag is connected and vacuum in the
inlet syrup line has returned to normal.